Publicação: Development of a voltammetric sensor for chromium(VI) determination in wastewater sample
dc.contributor.author | Bergamini, Marcio F. | |
dc.contributor.author | dos Santos, Daniela P. | |
dc.contributor.author | Zanoni, Maria Valnice Boldrin [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T15:27:56Z | |
dc.date.available | 2014-05-20T15:27:56Z | |
dc.date.issued | 2007-05-21 | |
dc.description.abstract | Screen-printed carbon electrode (SPCE) modified with poly-L-histidine film can be successfully applied for chromium(VI) determination based on its pre-concentration. Optimum adherence and stability of the POIY-L-histidine film was obtained by direct addition of PH solution 1% (w/v) on the electrode surface, followed by heating at 80 degrees C during 5 min. Linear response range, sensitivity and limit of detection were 0. 1-150 [mu mol L-1, 4. 13 LA mu mol L` and 0.046 mu mol L-1. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation, was measured as 3.2% for 10 experiments in 40 mu mol L-1 using the same electrode and 4.0% using screen-printed electrode as disposable sensor, respectively. The voltammetric sensor was applied to determination of Cr(VI) and indirect determination of Cr(III) in wastewater samples previously treated by a leather dyeing industry and the average recovery for these samples was around 97%. (C) 2006 Elsevier B.V. All rights reserved. | en |
dc.description.affiliation | UNESP, Dept Quim Analit, Inst Quim, BR-14801970 Araraquara, Brazil | |
dc.description.affiliationUnesp | UNESP, Dept Quim Analit, Inst Quim, BR-14801970 Araraquara, Brazil | |
dc.format.extent | 902-908 | |
dc.identifier | http://dx.doi.org/10.1016/j.snb.2006.10.062 | |
dc.identifier.citation | Sensors and Actuators B-chemical. Lausanne: Elsevier B.V. Sa, v. 123, n. 2, p. 902-908, 2007. | |
dc.identifier.doi | 10.1016/j.snb.2006.10.062 | |
dc.identifier.issn | 0925-4005 | |
dc.identifier.orcid | 0000-0002-2296-1393 | |
dc.identifier.uri | http://hdl.handle.net/11449/37847 | |
dc.identifier.wos | WOS:000247060100037 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Sensors and Actuators B: Chemical | |
dc.relation.ispartofjcr | 5.667 | |
dc.relation.ispartofsjr | 1,406 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | chromium(VI) | pt |
dc.subject | stripping analysis | pt |
dc.subject | screen-printed modified electrode | pt |
dc.subject | poly-L-histidine | pt |
dc.title | Development of a voltammetric sensor for chromium(VI) determination in wastewater sample | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-2296-1393[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: