Logotipo do repositório
 

Publicação:
Biomechanical Evaluation of Platform Switching in Different Implant Protocols: Computed Tomography-Based Three-Dimensional Finite Element Analysis

dc.contributor.authorPessoa, Roberto S. [UNESP]
dc.contributor.authorVaz, Luis Geraldo [UNESP]
dc.contributor.authorMarcantonio, Elcio [UNESP]
dc.contributor.authorVander Sloten, Jos
dc.contributor.authorDuyck, Joke
dc.contributor.authorJaecques, Siegfried V. N.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionKatholieke Univ Leuven
dc.date.accessioned2013-09-30T18:33:13Z
dc.date.accessioned2014-05-20T13:45:16Z
dc.date.available2013-09-30T18:33:13Z
dc.date.available2014-05-20T13:45:16Z
dc.date.issued2010-09-01
dc.description.abstractPurpose: To evaluate the influence of platform switching on the biomechanical environment of implants in different placement and loading protocols. Materials and Methods: A computed tomography-based finite element model of a maxillary central incisor extraction socket was constructed containing a conical 13-mm external-hex implant with a 4.3-mm-diameter shoulder. Abutment models that were 4.3 mm and 3.8 mm in diameter were then imported and aligned to the implant. The 4.3-mm abutment edge matched perfectly the edge of the implant shoulder, while the 3.8-mm abutment assumed a platform-switching configuration. Then, immediately placed, immediately loaded, and osseointegrated (ie, conventional delayed loaded) protocols were simulated. Analysis of variance was used to interpret the data for peak equivalent strain (EQV strain) in the bone, bone-to-implant relative displacement, peak von Mises stress (EQV stress) in the abutment screw, and implant-abutment gap. Results: In the same clinical situation, the differences in the values of the assessed results were minor for abutments of different diameters. In addition, no statistically significant influence of the abutment diameter was seen on any of the evaluated biomechanical parameters, except for the bone-to-implant displacement, although this was observed in a rather low percentage. Nevertheless, a slightly higher EQV stress in the abutment screw was seen in all cases for the 3.8-mm-diameter abutment, although this was not statistically significant. Conclusion: Within the limitation of this finite element analysis, it can be concluded that a circumferential horizontal mismatch of 0.5 mm does not make an important contribution to the biomechanical environment of implants. Also, there seems to be no significant biomechanical drawback to the design rationale of reducing the abutment diameter to move the implant-abutment gap area away from the implant-bone interface. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:911-919en
dc.description.affiliationSão Paulo State Univ, Dept Diagnost & Surg, Div Periodont, São Paulo, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Dent Mat & Prosthesis, Div Dental Mat, São Paulo, Brazil
dc.description.affiliationKatholieke Univ Leuven, Div Biomech & Engn Design, Louvain, Belgium
dc.description.affiliationKatholieke Univ Leuven, Dept Dent Oral Pathol & Maxillo Facial Surg, BIOMAT Res Cluster, Louvain, Belgium
dc.description.affiliationUnespSão Paulo State Univ, Dept Diagnost & Surg, Div Periodont, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Dent Mat & Prosthesis, Div Dental Mat, São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipKatholieke Universiteit of Leuven
dc.description.sponsorshipE.U.
dc.description.sponsorshipIdFAPESP: 06/06844-2
dc.description.sponsorshipIdKatholieke Universiteit of Leuven: OT/06/58
dc.description.sponsorshipIdE.U.: QLK6-CT-2002-02442 IMLOAD
dc.format.extent911-919
dc.identifierhttp://www.quintpub.com/journals/omi/abstract.php?article_id=10141#.Ui9im8bks_Y
dc.identifier.citationInternational Journal of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 25, n. 5, p. 911-919, 2010.
dc.identifier.issn0882-2786
dc.identifier.lattes8547747556446020
dc.identifier.urihttp://hdl.handle.net/11449/15909
dc.identifier.wosWOS:000282055600006
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofInternational Journal of Oral & Maxillofacial Implants
dc.relation.ispartofjcr1.699
dc.relation.ispartofsjr1,576
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectfinite element analysisen
dc.subjectimmediate implant loadingen
dc.subjectimmediate implant placementen
dc.subjectplatform switchingen
dc.titleBiomechanical Evaluation of Platform Switching in Different Implant Protocols: Computed Tomography-Based Three-Dimensional Finite Element Analysisen
dc.typeArtigo
dcterms.licensehttp://www.quintpub.com/journals/jop/orderreprints.php
dcterms.rightsHolderQuintessence Publishing Co Inc
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes8547747556446020
unesp.author.orcid0000-0003-0916-1962[2]
unesp.author.orcid0000-0002-9660-4524[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: