Logotipo do repositório
 

Publicação:
Color stability of chemically activated reline resin after microwave disinfection: A 1-year clinical trial

dc.contributor.authorRibeiro, Roberta Chuqui [UNESP]
dc.contributor.authorGiampaolo, Eunice Teresinha [UNESP]
dc.contributor.authorIzumida, Fernanda Emiko [UNESP]
dc.contributor.authorPavarina, Ana Cláudia [UNESP]
dc.contributor.authorMoffa, Eduardo Buozi [UNESP]
dc.contributor.authorVergani, Carlos Eduardo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T02:04:19Z
dc.date.available2022-04-29T02:04:19Z
dc.date.issued2011-08-01
dc.description.abstractPurpose: To evaluate the effect of microwave disinfection on the color stability of a hard chairside reline resin after a 1-year service period. Methods: 40 adult patients aged between 30-75 years, who required denture reline treatment, participated in this study. Tokuyama Rebase II was used to reline complete maxillary dentures. The edentulous subjects were randomly divided into two groups (n=20) and dentures were cleansed according to two methods: CG (control group) - brushing with coconut soap and soft toothbrush; DG (disinfection group) - brushing according to previous methods and microwave disinfection once a week for 3 minutes at 650W. Color parameters in L *a *b * were recorded by spectrophotometer immediately after the reline, at 7 and 15 days, 1, 3, 6 and 9 months and 1 year post-placement. Data were analyzed by two-way repeated-measures ANOVA and Tukey tests (α= 0.05). Results: Color alteration values of DG were significantly lower than those of CG (P< 0.05). Color changes observed after 15 days were greater than values obtained at 7 days recall (P< 0.05). All color changes observed for the CG were considered noticeable (between 1.5 and 3.0 NBS). In DG, color change was slight (between 0.5 and 1.5 NBS). There were statistically significant differences between L * values obtained initially and after 3 months, between 15 days and 3 months and between 15 days and 1 year (P< 0.05). No significant differences were observed between group and time for the parameters a * and b *.en
dc.description.affiliationAraraquara Dental School UNESP, R. Humaitá, no 1680, CEP 14801-903 Araraquara, São Paulo
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araraquara Dental School Paulista State University (UNESP), Araraquara, São Paulo
dc.description.affiliationUnespAraraquara Dental School UNESP, R. Humaitá, no 1680, CEP 14801-903 Araraquara, São Paulo
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araraquara Dental School Paulista State University (UNESP), Araraquara, São Paulo
dc.format.extent200-204
dc.identifier.citationAmerican Journal of Dentistry, v. 24, n. 4, p. 200-204, 2011.
dc.identifier.issn0894-8275
dc.identifier.scopus2-s2.0-82055196669
dc.identifier.urihttp://hdl.handle.net/11449/226608
dc.language.isoeng
dc.relation.ispartofAmerican Journal of Dentistry
dc.sourceScopus
dc.titleColor stability of chemically activated reline resin after microwave disinfection: A 1-year clinical trialen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos