Logotipo do repositório
 

Publicação:
Bond strength of adhesive restorations to Er : YAG laser-treated dentin

dc.contributor.authorMalta, D. A. M. P.
dc.contributor.authorKreidler, M. A. M.
dc.contributor.authorVilla, G. E.
dc.contributor.authorde Andrade, M. F.
dc.contributor.authorFontana, C. R.
dc.contributor.authorLizarelli, R. F. Z.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-20T13:46:54Z
dc.date.available2014-05-20T13:46:54Z
dc.date.issued2007-02-01
dc.description.abstractBackground and Objective: evaluate the adhesion of adhesive restorations with and without a base of resin-modified glass-ionomer cement (RMGIC) to dentin irradiated with Er:YAG laser.Study Design/Materials and Methods: Twenty-four human molar teeth were divided into 6 groups (n=4): G1) 37% Phosphoric acid (PA) + Adhesive system (Ad) + Composite resin (CR); G2) RMGIC + CR; G3) Laser (60mJ-5Hz-20s) + PA + Ad + CR; G4) Laser (60 mJ-5 Hz-20 s) + RMGIC + CR; G5) Laser (100mJ-5Hz-20s) + PA + Ad + CR; G6) Laser (100mJ-5Hz-20s) + RMGIC + CR. Teeth were prepared, restored and cut into specimens, according to the treatment proposed and to methodology for microtensile test. Data were submitted to ANOVA and Tukey statistical tests (alpha=5%).Results:. The mean values for adhesion (MPa) and standard deviation (+/- SD) were: G1) 26.30(+/- 4.50), G2) 5.34(+/- 2.87), G3) 21.16(+/- 6.01), G4) 5.22(+/- 1.52), G5) 22.23(+/- 4.98), G6) 5.25(+/- 3.08).Conclusion: the use of Er:YAG laser did not influence on the restorations adhesion.en
dc.description.affiliationAraraquara State Univ São Paulo, Dept Operat Dent, FOAr UNESP, BR-14801903 Araraquara, SP, Brazil
dc.description.affiliationIFSC USP, Phyd Dept & Sci Mat, Inst Phys Sao Carlos, BR-13560970 Sao Carlos, Brazil
dc.description.affiliationAraraquara State Univ São Paulo, Diag Dept & Surg, BR-14801903 Araraquara, SP, Brazil
dc.description.affiliationUnespAraraquara State Univ São Paulo, Dept Operat Dent, FOAr UNESP, BR-14801903 Araraquara, SP, Brazil
dc.description.affiliationUnespAraraquara State Univ São Paulo, Diag Dept & Surg, BR-14801903 Araraquara, SP, Brazil
dc.format.extent153-156
dc.identifierhttp://dx.doi.org/10.1002/lapl.200610085
dc.identifier.citationLaser Physics Letters. Weinheim: Wiley-v C H Verlag Gmbh, v. 4, n. 2, p. 153-156, 2007.
dc.identifier.doi10.1002/lapl.200610085
dc.identifier.issn1612-2011
dc.identifier.lattes2897622509429759
dc.identifier.urihttp://hdl.handle.net/11449/16640
dc.identifier.wosWOS:000244232100011
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofLaser Physics Letters
dc.relation.ispartofjcr2.240
dc.relation.ispartofsjr0,818
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectadhesionpt
dc.subjectdentinpt
dc.subjectEr : YAG laserpt
dc.subjectmicro-tensile bond strengthpt
dc.subjectresin-modified glass-ionomer cementpt
dc.titleBond strength of adhesive restorations to Er : YAG laser-treated dentinen
dc.typeArtigopt
dcterms.licensehttp://iopscience.iop.org/page/copyright
dcterms.rightsHolderWiley-Blackwell
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes2897622509429759
unesp.author.lattes5168319315634298[5]
unesp.author.orcid0000-0002-9135-3690[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: