Publicação: Machined and plastic copings in three-element prostheses with different types of implant-abutment joints: a strain gauge comparative analysis
dc.contributor.author | Nishioka, Renato Sussumu [UNESP] | |
dc.contributor.author | Braulino de Melo Nishioka, Lea Nogueira | |
dc.contributor.author | Abreu, Celina Wanderley [UNESP] | |
dc.contributor.author | Oliveira de Vasconcellos, Luis Gustavo | |
dc.contributor.author | Balducci, Ivan [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | CETEC | |
dc.date.accessioned | 2014-05-20T14:05:03Z | |
dc.date.available | 2014-05-20T14:05:03Z | |
dc.date.issued | 2010-05-01 | |
dc.description.abstract | Objective: Using strain gauge (SG) analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of hexagonal connection would generate different microstrains and the type of copings would produce similar microstrains after prosthetic screws had been tightened onto microunit abutments. Materials and methods: Three dental implants with external (EH) and internal (IH) hexagonal configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto their respective implant groups, applying a torque of 20 Ncm. Machined Co-Cr copings (M) and plastic prosthetic copings (P) were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in Co-Cr alloy (n=5), forming four groups: G1) EH/M; G2) EH/P; G3) IH/M and G4) IH/P. Four SGs were bonded onto the surface of the block tangentially to the implants, SG 1 mesially to implant 1, SG 2 and SG 3 mesially and distally to implant 2, respectively, and SG 4 distally to implant 3. The superstructure's occlusal screws were tightened onto microunit abutments with 10 Ncm torque using a manual torque driver. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed statistically by ANOVA and Tukey's test (p<0.05). Results: Microstrain values of each group were: G1=338.1 +/- 223.0 mu epsilon; G2=363.9 +/- 190.9 mu epsilon; G3=415.1 +/- 53.5 mu epsilon; G4=363.9 +/- 190.9 mu epsilon. No statistically difference was found between EH and IH, regardless of the type of copings (p>0.05). The hypotheses were partially accepted. Conclusions: It was concluded that the type of hexagonal connection and coping presented similar mechanical behavior under tightening conditions. | en |
dc.description.affiliation | UNESP, Fac Odontol Sao Jose dos Campos, Dept Mat Odontol & Protese, Sao Jose dos Campos Dent Sch, BR-12245000 Sao Jose Dos Campos, SP, Brazil | |
dc.description.affiliation | Dept Mech Engn CETEC, Sao Jose Dos Campos, Brazil | |
dc.description.affiliation | UNESP, Sao Jose dos Campos Dent Sch, Dept Community Dent & Pediat Clin, BR-12245000 Sao Jose Dos Campos, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Fac Odontol Sao Jose dos Campos, Dept Mat Odontol & Protese, Sao Jose dos Campos Dent Sch, BR-12245000 Sao Jose Dos Campos, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Sao Jose dos Campos Dent Sch, Dept Community Dent & Pediat Clin, BR-12245000 Sao Jose Dos Campos, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 07/53293-4 | |
dc.format.extent | 225-230 | |
dc.identifier | http://dx.doi.org/10.1590/S1678-77572010000300005 | |
dc.identifier.citation | Journal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 18, n. 3, p. 225-230, 2010. | |
dc.identifier.file | S1678-77572010000300005-en.pdf | |
dc.identifier.issn | 1678-7757 | |
dc.identifier.lattes | 0056660842284397 | |
dc.identifier.orcid | 0000-0002-1458-601X | |
dc.identifier.scielo | S1678-77572010000300005 | |
dc.identifier.uri | http://hdl.handle.net/11449/22814 | |
dc.identifier.wos | WOS:000281692000004 | |
dc.language.iso | eng | |
dc.publisher | Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru | |
dc.relation.ispartof | Journal of Applied Oral Science | |
dc.relation.ispartofjcr | 1.709 | |
dc.relation.ispartofsjr | 0,645 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | Biomechanics | en |
dc.subject | Dental implants | en |
dc.subject | Dental prosthesis | en |
dc.subject | Implant-supported dental prosthesis | en |
dc.title | Machined and plastic copings in three-element prostheses with different types of implant-abutment joints: a strain gauge comparative analysis | en |
dc.type | Resenha | |
dcterms.license | http://www.scielo.br/revistas/jaos/paboutj.htm | |
dcterms.rightsHolder | Univ São Paulo Fac Odontologia Bauru | |
dspace.entity.type | Publication | |
unesp.author.lattes | 0056660842284397[1] | |
unesp.author.orcid | 0000-0002-1458-601X[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |
unesp.department | Odontologia Social e Clínica Infantil - ICT | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- S1678-77572010000300005-en.pdf
- Tamanho:
- 1.1 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: