Logotipo do repositório
 

Publicação:
Machined and plastic copings in three-element prostheses with different types of implant-abutment joints: a strain gauge comparative analysis

dc.contributor.authorNishioka, Renato Sussumu [UNESP]
dc.contributor.authorBraulino de Melo Nishioka, Lea Nogueira
dc.contributor.authorAbreu, Celina Wanderley [UNESP]
dc.contributor.authorOliveira de Vasconcellos, Luis Gustavo
dc.contributor.authorBalducci, Ivan [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionCETEC
dc.date.accessioned2014-05-20T14:05:03Z
dc.date.available2014-05-20T14:05:03Z
dc.date.issued2010-05-01
dc.description.abstractObjective: Using strain gauge (SG) analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of hexagonal connection would generate different microstrains and the type of copings would produce similar microstrains after prosthetic screws had been tightened onto microunit abutments. Materials and methods: Three dental implants with external (EH) and internal (IH) hexagonal configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto their respective implant groups, applying a torque of 20 Ncm. Machined Co-Cr copings (M) and plastic prosthetic copings (P) were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in Co-Cr alloy (n=5), forming four groups: G1) EH/M; G2) EH/P; G3) IH/M and G4) IH/P. Four SGs were bonded onto the surface of the block tangentially to the implants, SG 1 mesially to implant 1, SG 2 and SG 3 mesially and distally to implant 2, respectively, and SG 4 distally to implant 3. The superstructure's occlusal screws were tightened onto microunit abutments with 10 Ncm torque using a manual torque driver. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed statistically by ANOVA and Tukey's test (p<0.05). Results: Microstrain values of each group were: G1=338.1 +/- 223.0 mu epsilon; G2=363.9 +/- 190.9 mu epsilon; G3=415.1 +/- 53.5 mu epsilon; G4=363.9 +/- 190.9 mu epsilon. No statistically difference was found between EH and IH, regardless of the type of copings (p>0.05). The hypotheses were partially accepted. Conclusions: It was concluded that the type of hexagonal connection and coping presented similar mechanical behavior under tightening conditions.en
dc.description.affiliationUNESP, Fac Odontol Sao Jose dos Campos, Dept Mat Odontol & Protese, Sao Jose dos Campos Dent Sch, BR-12245000 Sao Jose Dos Campos, SP, Brazil
dc.description.affiliationDept Mech Engn CETEC, Sao Jose Dos Campos, Brazil
dc.description.affiliationUNESP, Sao Jose dos Campos Dent Sch, Dept Community Dent & Pediat Clin, BR-12245000 Sao Jose Dos Campos, SP, Brazil
dc.description.affiliationUnespUNESP, Fac Odontol Sao Jose dos Campos, Dept Mat Odontol & Protese, Sao Jose dos Campos Dent Sch, BR-12245000 Sao Jose Dos Campos, SP, Brazil
dc.description.affiliationUnespUNESP, Sao Jose dos Campos Dent Sch, Dept Community Dent & Pediat Clin, BR-12245000 Sao Jose Dos Campos, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 07/53293-4
dc.format.extent225-230
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572010000300005
dc.identifier.citationJournal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 18, n. 3, p. 225-230, 2010.
dc.identifier.fileS1678-77572010000300005-en.pdf
dc.identifier.issn1678-7757
dc.identifier.lattes0056660842284397
dc.identifier.orcid0000-0002-1458-601X
dc.identifier.scieloS1678-77572010000300005
dc.identifier.urihttp://hdl.handle.net/11449/22814
dc.identifier.wosWOS:000281692000004
dc.language.isoeng
dc.publisherUniversidade de São Paulo (USP), Faculdade de Odontologia de Bauru
dc.relation.ispartofJournal of Applied Oral Science
dc.relation.ispartofjcr1.709
dc.relation.ispartofsjr0,645
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectBiomechanicsen
dc.subjectDental implantsen
dc.subjectDental prosthesisen
dc.subjectImplant-supported dental prosthesisen
dc.titleMachined and plastic copings in three-element prostheses with different types of implant-abutment joints: a strain gauge comparative analysisen
dc.typeResenha
dcterms.licensehttp://www.scielo.br/revistas/jaos/paboutj.htm
dcterms.rightsHolderUniv São Paulo Fac Odontologia Bauru
dspace.entity.typePublication
unesp.author.lattes0056660842284397[1]
unesp.author.orcid0000-0002-1458-601X[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt
unesp.departmentOdontologia Social e Clínica Infantil - ICTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1678-77572010000300005-en.pdf
Tamanho:
1.1 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: