Logotipo do repositório
 

Publicação:
Evaluation of various methods of methylene blue removal from the post space after photodynamic therapy on the bonding interface using different resin cementation systems

dc.contributor.authorAlencar, Cristiane de Melo [UNESP]
dc.contributor.authorCosta, Joatan Lucas de Sousa Gomes [UNESP]
dc.contributor.authorJassé, Fernanda Ferreira de Albuquerque
dc.contributor.authorCampos, Edson Alves de [UNESP]
dc.contributor.authorDantas, Andréa Abi Rached [UNESP]
dc.contributor.authorKuga, Milton Carlos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal do Pará (UFPA)
dc.date.accessioned2021-06-25T10:57:27Z
dc.date.available2021-06-25T10:57:27Z
dc.date.issued2021-06-01
dc.description.abstractBackground: To evaluate the effects of three protocols for removing 0.01 % methylene blue from the post space after photodynamic therapy on bond strength and tag formation in the dentin of the fiber post space, using a conventional cementation system with an etch-and-rinse or universal adhesive system. Methods: Sixty human canines were endodontically treated for fiber post cementation. The specimens were randomized into 6 groups (n = 10): G1, G2, G3, G4, G5, and G6. The G1, G2, and G3 groups were irrigated with saline solution, 2.5 % sodium hypochlorite (NaOCl), and 2.5 % NaOCl, agitated by passive ultrasonic irrigation (PUI), respectively. In these groups, a conventional cementation system with etch-and-rinse adhesive was used. The G4, G5, and G6 groups were irrigated with the respective solutions mentioned above and cemented using a conventional cementation system with universal adhesive. Tag formation in the dentin was evaluated by confocal laser scanning microscopy. The push-out bond strength test was performed on three thirds of the specimens. Results: In the cervical and middle thirds, the greatest extent of dentin tag formation occurred in the G1 (p = 0.023 and p = 0.033, respectively). In the apical third, G1, G2, and G3 demonstrated similar tag formation between themselves (p = 0.089). In the cervical and middle thirds, G4 demonstrated the highest bond strength when compared to the other groups (p < 0.05). Conclusion: The protocols for removing 0.01 % methylene blue with NaOCl, irrespective of the involvement of passive ultrasonic irrigation, negatively effects the bond strength and tag formation in the dentin of the post space.en
dc.description.affiliationDepartment of Restorative Dentistry Araraquara School of Dentistry São Paulo State University – UNESP, Humaitá Street, No. 1680
dc.description.affiliationSchool of Dentistry Federal University of Pará – UFPA, Augusto Corrêa Street, No. 1 - Guamá
dc.description.affiliationUnespDepartment of Restorative Dentistry Araraquara School of Dentistry São Paulo State University – UNESP, Humaitá Street, No. 1680
dc.identifierhttp://dx.doi.org/10.1016/j.pdpdt.2021.102264
dc.identifier.citationPhotodiagnosis and Photodynamic Therapy, v. 34.
dc.identifier.doi10.1016/j.pdpdt.2021.102264
dc.identifier.issn1873-1597
dc.identifier.issn1572-1000
dc.identifier.scopus2-s2.0-85103769533
dc.identifier.urihttp://hdl.handle.net/11449/207572
dc.language.isoeng
dc.relation.ispartofPhotodiagnosis and Photodynamic Therapy
dc.sourceScopus
dc.subjectDental bonding
dc.subjectFiber post
dc.subjectMethylene blue
dc.subjectPhotodynamic therapy
dc.subjectResin cements
dc.titleEvaluation of various methods of methylene blue removal from the post space after photodynamic therapy on the bonding interface using different resin cementation systemsen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.orcid0000-0002-0694-6863[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos