Publicação: Evaluation of various methods of methylene blue removal from the post space after photodynamic therapy on the bonding interface using different resin cementation systems
dc.contributor.author | Alencar, Cristiane de Melo [UNESP] | |
dc.contributor.author | Costa, Joatan Lucas de Sousa Gomes [UNESP] | |
dc.contributor.author | Jassé, Fernanda Ferreira de Albuquerque | |
dc.contributor.author | Campos, Edson Alves de [UNESP] | |
dc.contributor.author | Dantas, Andréa Abi Rached [UNESP] | |
dc.contributor.author | Kuga, Milton Carlos [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal do Pará (UFPA) | |
dc.date.accessioned | 2021-06-25T10:57:27Z | |
dc.date.available | 2021-06-25T10:57:27Z | |
dc.date.issued | 2021-06-01 | |
dc.description.abstract | Background: To evaluate the effects of three protocols for removing 0.01 % methylene blue from the post space after photodynamic therapy on bond strength and tag formation in the dentin of the fiber post space, using a conventional cementation system with an etch-and-rinse or universal adhesive system. Methods: Sixty human canines were endodontically treated for fiber post cementation. The specimens were randomized into 6 groups (n = 10): G1, G2, G3, G4, G5, and G6. The G1, G2, and G3 groups were irrigated with saline solution, 2.5 % sodium hypochlorite (NaOCl), and 2.5 % NaOCl, agitated by passive ultrasonic irrigation (PUI), respectively. In these groups, a conventional cementation system with etch-and-rinse adhesive was used. The G4, G5, and G6 groups were irrigated with the respective solutions mentioned above and cemented using a conventional cementation system with universal adhesive. Tag formation in the dentin was evaluated by confocal laser scanning microscopy. The push-out bond strength test was performed on three thirds of the specimens. Results: In the cervical and middle thirds, the greatest extent of dentin tag formation occurred in the G1 (p = 0.023 and p = 0.033, respectively). In the apical third, G1, G2, and G3 demonstrated similar tag formation between themselves (p = 0.089). In the cervical and middle thirds, G4 demonstrated the highest bond strength when compared to the other groups (p < 0.05). Conclusion: The protocols for removing 0.01 % methylene blue with NaOCl, irrespective of the involvement of passive ultrasonic irrigation, negatively effects the bond strength and tag formation in the dentin of the post space. | en |
dc.description.affiliation | Department of Restorative Dentistry Araraquara School of Dentistry São Paulo State University – UNESP, Humaitá Street, No. 1680 | |
dc.description.affiliation | School of Dentistry Federal University of Pará – UFPA, Augusto Corrêa Street, No. 1 - Guamá | |
dc.description.affiliationUnesp | Department of Restorative Dentistry Araraquara School of Dentistry São Paulo State University – UNESP, Humaitá Street, No. 1680 | |
dc.identifier | http://dx.doi.org/10.1016/j.pdpdt.2021.102264 | |
dc.identifier.citation | Photodiagnosis and Photodynamic Therapy, v. 34. | |
dc.identifier.doi | 10.1016/j.pdpdt.2021.102264 | |
dc.identifier.issn | 1873-1597 | |
dc.identifier.issn | 1572-1000 | |
dc.identifier.scopus | 2-s2.0-85103769533 | |
dc.identifier.uri | http://hdl.handle.net/11449/207572 | |
dc.language.iso | eng | |
dc.relation.ispartof | Photodiagnosis and Photodynamic Therapy | |
dc.source | Scopus | |
dc.subject | Dental bonding | |
dc.subject | Fiber post | |
dc.subject | Methylene blue | |
dc.subject | Photodynamic therapy | |
dc.subject | Resin cements | |
dc.title | Evaluation of various methods of methylene blue removal from the post space after photodynamic therapy on the bonding interface using different resin cementation systems | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-0694-6863[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Odontologia Restauradora - FOAR | pt |