Logotipo do repositório
 

Publicação:
Rapid and sensitive ultra-high-pressure liquid chromatography method for quantification of antichagasic benznidazole in plasma: application in a preclinical pharmacokinetic study

dc.contributor.authorDavanço, Marcelo Gomes [UNESP]
dc.contributor.authorCampos, Michel Leandro de [UNESP]
dc.contributor.authorPeccinini, Rosângela Gonçalves [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-10-21T21:01:39Z
dc.date.available2015-10-21T21:01:39Z
dc.date.issued2015-07-01
dc.description.abstractBenznidazole (BNZ) and nifurtimox are the only drugs available for treating Chagas disease. In this work, we validated a bioanalytical method for the quantification of BNZ in plasma aimed at improving sensitivity and time of analysis compared with the assays already published. Furthermore, we demonstrated the application of the method in a preclinical pharmacokinetic study after administration of a single oral dose of BNZ in Wistar rats. A Waters (R) Acquity UHPLC system equipped with a UV-vis detector was employed. The method was established using an Acquity (R) UHPLC HSS SB C-18 protected by an Acquity (R) UHPLC HSS SB C-18 VanGuard guard column and detection at 324 nm(.) The mobile phase consisted of ultrapure water-acetonitrile (65:35), and elution was isocratic. The mobile phase flow rate was 0.55 mL/min, the volume of injection was 1 L, and the run time was just 2 min. The samples were kept at 25 degrees C until injection and the column at 45 degrees C for the chromatographic separation. The sample preparation was performed by a rapid protein precipitation with acetonitrile. The linear concentration range was 0.15-20 mu g/mL. The pharmacokinetic parameters of BNZ in rats were determined and the method was considered sensitive, fast and suitable for application in pharmacokinetic studies.en
dc.description.affiliationUnespUniversidade Estadual Paulista, Departamento de Princípios Ativos Naturais e Toxicologia, Faculdade de Ciências Farmacêuticas de Araraquara
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipInstituto Nacional de Ciência e Tecnologia para Inovação Farmacêutica (INCT-IF)
dc.description.sponsorshipIdFAPESP: 09/51075-5
dc.description.sponsorshipIdFAPESP: 11/11239-9
dc.format.extent1008-1015
dc.identifierhttp://onlinelibrary.wiley.com/doi/10.1002/bmc.3386/abstract
dc.identifier.citationBiomedical Chromatography. Hoboken: Wiley-blackwell, v. 29, n. 7, p. 1008-1015, 2015.
dc.identifier.doi10.1002/bmc.3386
dc.identifier.issn0269-3879
dc.identifier.lattes1066743423929093
dc.identifier.urihttp://hdl.handle.net/11449/129405
dc.identifier.wosWOS:000356694000007
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofBiomedical Chromatography
dc.relation.ispartofjcr1.688
dc.relation.ispartofsjr0,490
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectBenznidazoleen
dc.subjectChagas diseaseen
dc.subjectPharmacokinetic parametersen
dc.subjectUltra-high pressure liquid chromatographyen
dc.subjectValidation methoden
dc.subjectBioanalytical methoden
dc.titleRapid and sensitive ultra-high-pressure liquid chromatography method for quantification of antichagasic benznidazole in plasma: application in a preclinical pharmacokinetic studyen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-Blackwell
dspace.entity.typePublication
relation.isOrgUnitOfPublication95697b0b-8977-4af6-88d5-c29c80b5ee92
relation.isOrgUnitOfPublication.latestForDiscovery95697b0b-8977-4af6-88d5-c29c80b5ee92
unesp.author.lattes1066743423929093
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Farmacêuticas, Araraquarapt
unesp.departmentPrincípios Ativos Naturais e Toxicologia - FCFpt

Arquivos