Logotipo do repositório
 

Publicação:
Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial dentures

dc.contributor.authorMendes Tribst, Joao Paulo [UNESP]
dc.contributor.authorOliveira Dal Piva, Amanda Maria de [UNESP]
dc.contributor.authorSouto Borges, Alexandre Luiz [UNESP]
dc.contributor.authorAraujo, Rodrigo Maximo [UNESP]
dc.contributor.authorFerraz da Silva, Joao Mauricio [UNESP]
dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.authorKleverlaan, Cornelis Johannes
dc.contributor.authorJager, Niek de
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Amsterdam
dc.contributor.institutionVrije Univ
dc.date.accessioned2020-12-10T19:47:28Z
dc.date.available2020-12-10T19:47:28Z
dc.date.issued2020-02-01
dc.description.abstractObjectives. This study aimed to evaluate the effect of different materials and undercut on the removal force and stress distribution in the supporting tooth and in the circumferential clasp used in removable partial prosthesis. Methods. Upper molars prepared for Akers circumferential clasp with retention and opposing arm were modeled, scanned, elaborated with CAD software and the geometries imported in FEA and analyzed. Six different materials were selected for the clasp (Polyamide, Poly-oxymethylene, Polyetheretherketone - PEEK, Gold alloy, Titanium and CoCr) and 3 different undercuts (0.25, 0.50 and 0.75 mm), totaling 18 groups. Results. The clasps presented greater stress in their structure and potentially greater damage to the dental enamel when made with rigid materials and with more undercut; however, they presented greater ability to remain in position. Significance. Polyamide with a higher undercut is an esthetic alternative to rigid metallic clasps. It showed promising behavior because it strongly reduces the damage to the enamel, and even with an undercut of 0.75, the retention is lower than for CoCr with a 0.25 undercut, and this retention might still be sufficient. Polyoxymethylene and Polyetheretherketone (PEEK) are not suitable materials for the clasps, because the maximum stress occurring during removal with higher undercuts is higher than the material strength. (C) 2019 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.en
dc.description.affiliationSao Paulo State Univ Unesp, Inst Sci & Technol, PhD Grad Program Restorat Dent, Av Engn Francisco Jose Longo 777, BR-12245000 Sao Jose Dos Campos, SP, Brazil
dc.description.affiliationUniv Amsterdam, Acad Ctr Dent Amsterdam ACTA, Dept Dent Mat Sci, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Noord Holland, Netherlands
dc.description.affiliationVrije Univ, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Noord Holland, Netherlands
dc.description.affiliationUnespSao Paulo State Univ Unesp, Inst Sci & Technol, PhD Grad Program Restorat Dent, Av Engn Francisco Jose Longo 777, BR-12245000 Sao Jose Dos Campos, SP, Brazil
dc.format.extent179-186
dc.identifierhttp://dx.doi.org/10.1016/j.dental.2019.11.027
dc.identifier.citationDental Materials. Oxford: Elsevier Sci Ltd, v. 36, n. 2, p. 179-186, 2020.
dc.identifier.doi10.1016/j.dental.2019.11.027
dc.identifier.issn0109-5641
dc.identifier.urihttp://hdl.handle.net/11449/196514
dc.identifier.wosWOS:000508632600004
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofDental Materials
dc.sourceWeb of Science
dc.subjectRemovable partial denture
dc.subjectFinite element analysis
dc.subjectProsthetic dentistry
dc.subjectRetentive force
dc.subjectClasp
dc.subjectNon-Metal clasp
dc.subjectRetention
dc.titleEffect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial denturesen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.orcid0000-0001-6372-6333[5]
unesp.author.orcid0000-0003-0077-3161[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentOdontologia Restauradora - ICTpt

Arquivos