Logotipo do repositório
 

Publicação:
Influence of agitation methods of irrigants after methylene blue-mediated PDT on the bonding interface of a fiber post cementation system

dc.contributor.authorGalvani, Lucas David [UNESP]
dc.contributor.authorCosta, Joatan Lucas de Sousa Gomes [UNESP]
dc.contributor.authorBesegato, João Felipe [UNESP]
dc.contributor.authorZaniboni, Joissi Ferrari [UNESP]
dc.contributor.authorEscalante-Otárola, Wilfredo Gustavo [UNESP]
dc.contributor.authorKuga, Milton Carlos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T08:38:20Z
dc.date.available2022-04-29T08:38:20Z
dc.date.issued2022-03-01
dc.description.abstractBackground: This study evaluated the effects of final agitation methods of irrigants to remove methylene blue and sodium hypochlorite residues after PDT-assisted endodontic treatment on the bond strength of fiber posts cemented with etch-and-rinse adhesive and conventional resin cement. Methods: Ninety bovine teeth were endodontically treated. In sequence, post space preparation followed by methylene blue-mediated PDT and sodium hypochlorite (NaOCl) irrigation were performed. Six final irrigations protocols for dye and NaOCl removal were performed prior to cementation with etch-and-rinse adhesive (Adper Scocthbond Multipurpose) and conventional dual resin cement (RelyX ARC): Conventional endodontic irrigation (CEI), passive ultrasonic irrigation (PUI), mechanical agitation with XP Endo Finisher (XPF), XP Clean (XPC) or Easy Clean (ECL) and distilled water (NCO - control). After fiber post cementation, push-out bond strength test was performed at different thirds of the post space. Failure mode was also analyzed. ANOVA and Tukey's post-hoc test was used for data analysis (α=5%). Results: PUI, XPF e XPC protocols showed the highest bond strength values with no difference among them (p > 0.05), although they were similar to NCO, regardless of the post space third. CEI e ECL showed similar bond strength values, regardless of the third (p > 0.05). Adhesive failure was the most incident for CEI and ECL, while mixed and cohesive failures were predominant in PUI, XPF, XPC and NCO groups. Conclusions: Mechanical agitation of distilled water with XPF, XPC and PUI after methylene blue-mediated PDT and irrigation with 2.5% sodium hypochlorite promoted bond strength of the resin cementation system in post space dentin comparable to control group.en
dc.description.affiliationDepartment of Restorative Dentistry School of Dentistry Araraquara Sao Paulo State University – UNESP, SP
dc.description.affiliationUnespDepartment of Restorative Dentistry School of Dentistry Araraquara Sao Paulo State University – UNESP, SP
dc.identifierhttp://dx.doi.org/10.1016/j.pdpdt.2021.102708
dc.identifier.citationPhotodiagnosis and Photodynamic Therapy, v. 37.
dc.identifier.doi10.1016/j.pdpdt.2021.102708
dc.identifier.issn1873-1597
dc.identifier.issn1572-1000
dc.identifier.scopus2-s2.0-85122543895
dc.identifier.urihttp://hdl.handle.net/11449/230193
dc.language.isoeng
dc.relation.ispartofPhotodiagnosis and Photodynamic Therapy
dc.sourceScopus
dc.subjectAdhesion
dc.subjectBond strength
dc.subjectFiber posts
dc.subjectMechanical agitation
dc.subjectMethylene blue
dc.subjectPhotodynamic therapy
dc.subjectRoot canals
dc.titleInfluence of agitation methods of irrigants after methylene blue-mediated PDT on the bonding interface of a fiber post cementation systemen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos