Publicação: Influence of agitation methods of irrigants after methylene blue-mediated PDT on the bonding interface of a fiber post cementation system
dc.contributor.author | Galvani, Lucas David [UNESP] | |
dc.contributor.author | Costa, Joatan Lucas de Sousa Gomes [UNESP] | |
dc.contributor.author | Besegato, João Felipe [UNESP] | |
dc.contributor.author | Zaniboni, Joissi Ferrari [UNESP] | |
dc.contributor.author | Escalante-Otárola, Wilfredo Gustavo [UNESP] | |
dc.contributor.author | Kuga, Milton Carlos [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.date.accessioned | 2022-04-29T08:38:20Z | |
dc.date.available | 2022-04-29T08:38:20Z | |
dc.date.issued | 2022-03-01 | |
dc.description.abstract | Background: This study evaluated the effects of final agitation methods of irrigants to remove methylene blue and sodium hypochlorite residues after PDT-assisted endodontic treatment on the bond strength of fiber posts cemented with etch-and-rinse adhesive and conventional resin cement. Methods: Ninety bovine teeth were endodontically treated. In sequence, post space preparation followed by methylene blue-mediated PDT and sodium hypochlorite (NaOCl) irrigation were performed. Six final irrigations protocols for dye and NaOCl removal were performed prior to cementation with etch-and-rinse adhesive (Adper Scocthbond Multipurpose) and conventional dual resin cement (RelyX ARC): Conventional endodontic irrigation (CEI), passive ultrasonic irrigation (PUI), mechanical agitation with XP Endo Finisher (XPF), XP Clean (XPC) or Easy Clean (ECL) and distilled water (NCO - control). After fiber post cementation, push-out bond strength test was performed at different thirds of the post space. Failure mode was also analyzed. ANOVA and Tukey's post-hoc test was used for data analysis (α=5%). Results: PUI, XPF e XPC protocols showed the highest bond strength values with no difference among them (p > 0.05), although they were similar to NCO, regardless of the post space third. CEI e ECL showed similar bond strength values, regardless of the third (p > 0.05). Adhesive failure was the most incident for CEI and ECL, while mixed and cohesive failures were predominant in PUI, XPF, XPC and NCO groups. Conclusions: Mechanical agitation of distilled water with XPF, XPC and PUI after methylene blue-mediated PDT and irrigation with 2.5% sodium hypochlorite promoted bond strength of the resin cementation system in post space dentin comparable to control group. | en |
dc.description.affiliation | Department of Restorative Dentistry School of Dentistry Araraquara Sao Paulo State University – UNESP, SP | |
dc.description.affiliationUnesp | Department of Restorative Dentistry School of Dentistry Araraquara Sao Paulo State University – UNESP, SP | |
dc.identifier | http://dx.doi.org/10.1016/j.pdpdt.2021.102708 | |
dc.identifier.citation | Photodiagnosis and Photodynamic Therapy, v. 37. | |
dc.identifier.doi | 10.1016/j.pdpdt.2021.102708 | |
dc.identifier.issn | 1873-1597 | |
dc.identifier.issn | 1572-1000 | |
dc.identifier.scopus | 2-s2.0-85122543895 | |
dc.identifier.uri | http://hdl.handle.net/11449/230193 | |
dc.language.iso | eng | |
dc.relation.ispartof | Photodiagnosis and Photodynamic Therapy | |
dc.source | Scopus | |
dc.subject | Adhesion | |
dc.subject | Bond strength | |
dc.subject | Fiber posts | |
dc.subject | Mechanical agitation | |
dc.subject | Methylene blue | |
dc.subject | Photodynamic therapy | |
dc.subject | Root canals | |
dc.title | Influence of agitation methods of irrigants after methylene blue-mediated PDT on the bonding interface of a fiber post cementation system | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Odontologia Restauradora - FOAR | pt |