Logotipo do repositório
 

Publicação:
Stress Analysis in Simulation Models With or Without Implant Threads Representation

dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorGomes, Erica Alves [UNESP]
dc.contributor.authorRicardo Barao, Valentim Adelino [UNESP]
dc.contributor.authorSousa, Edson Antonio Capello [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:10:32Z
dc.date.accessioned2014-05-20T13:43:32Z
dc.date.available2013-09-30T18:10:32Z
dc.date.available2014-05-20T13:43:32Z
dc.date.issued2009-11-01
dc.description.abstractPurpose: This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis. Materials and Methods: Two-dimensional FE models that reproduced a frontal section of edentulous mandibular posterior bone were constructed using a standard crown/implant/screw system representation. To evaluate the effect of implant threads, two models were created: a model in which the implant threads were accurately simulated (precise model) and a model in which implants with a smooth surface (press-fit implant) were used (simplified model). An evaluation was performed on ANSYS software, in which a load of 133 N was applied at a 30-degree angulation and 2 mm off-axis from the long axis of the implant on the models, The Von Mises stresses were measured. Results: The precise model (1.45 MPa) showed higher maximum stress values than the simplified model (1.2 MPa). Whereas in the cortical bone, the stress values differed by about 36% (292.95 MPa for the precise model and 401.14 MPa for the simplified model), in trabecular bone (19.35 MPa and 20.35 MPa, respectively), the stress distribution and stress values were similar. Stress concentrations occurred around the implant neck and the implant apex. Conclusions: Considering implant and cortical bone analysis, remarkable differences in stress values were found between the models. Although the models showed different absolute stress values, the stress distribution was similar. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:1040-1044en
dc.description.affiliationSão Paulo State Univ, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, São Paulo, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Mech Engn, Bauru Engn Sch, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Mech Engn, Bauru Engn Sch, São Paulo, Brazil
dc.format.extent1040-1044
dc.identifierhttp://www.quintpub.com/journals/omi/abstract.php?article_id=6855#.Ui9msMbks_Y
dc.identifier.citationInternational Journal of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 24, n. 6, p. 1040-1044, 2009.
dc.identifier.issn0882-2786
dc.identifier.lattes4438747643373395
dc.identifier.urihttp://hdl.handle.net/11449/15198
dc.identifier.wosWOS:000273295800007
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofInternational Journal of Oral & Maxillofacial Implants
dc.relation.ispartofjcr1.699
dc.relation.ispartofsjr1,576
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectbiomechanicsen
dc.subjectdental implantsen
dc.subjectfinite element analysisen
dc.subjectthreadsen
dc.titleStress Analysis in Simulation Models With or Without Implant Threads Representationen
dc.typeArtigopt
dcterms.licensehttp://www.quintpub.com/journals/jop/orderreprints.php
dcterms.rightsHolderQuintessence Publishing Co Inc
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes8934648262859482
unesp.author.orcid0000-0002-8903-0737[1]
unesp.author.orcid0000-0002-6391-9917[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Baurupt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentEngenharia Mecânica - FEBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: