Publicação: Effect of splinting in accuracy of two implants impression techniques
dc.contributor.author | Avila, Érica Dorigatti de [UNESP] | |
dc.contributor.author | Moraes, Fernanda de Matos [UNESP] | |
dc.contributor.author | Castanharo, Sabrina Maria [UNESP] | |
dc.contributor.author | Del´Acqua, Marcelo Antonialli | |
dc.contributor.author | Mollo Júnior, Francisco de Assis [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Centro Universitário de Araraquara (UNIARA) | |
dc.date.accessioned | 2015-08-06T16:13:11Z | |
dc.date.available | 2015-08-06T16:13:11Z | |
dc.date.issued | 2014 | |
dc.description.abstract | Because there is no consensus in the literature about the need for a splint between copings, the aim of this study was to evaluate, in vitro, the accuracy of 2 impression techniques for implant-supported prostheses. A master cast was fabricated with four parallel implant abutment analogs and a passive framework. Two groups with 5 casts each were formed: Group 1 (squared impression copings with no splint: S) and Group 2 (splinted squared impression copings, using metal drill burs and Pattern resin: SS). The impression material used was polyvinyl siloxane with open trays for standard preparation of the casts. For each cast, the framework was positioned, and a titanium screw was tightened with 10 N·cm torque in analog A, after which measurements of the abutment-framework interface gaps were performed at analogs C and D. This process was repeated for analog D. These measurements were analyzed using software. A one-way analysis of variance (ANOVA) with a confidence interval of 95% was used to analyze the data. Significant differences were detected between S and SS in relation to the master cast (P ≤ 0.05). The median values of the abutment-framework interface gaps were as follows: master cast: 39.64 μm; squared impression copings with no splint: 205.86 μm; splinted squared impression copings: 99.19 μm. Under the limitations of this study, the technique presented for Group 2 produces better results compared with the technique used for Group 1. | en |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de Araraquara | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 2009/14882-0 | |
dc.format.extent | 633-639 | |
dc.identifier | http://www.joionline.org/doi/full/10.1563/AAID-JOI-D-12-00198?= | |
dc.identifier.citation | The Journal of Oral Implantology, v. 40, n. 6, p. 633-639, 2014. | |
dc.identifier.doi | 10.1563/AAID-JOI-D-12-00198 | |
dc.identifier.issn | 0160-6972 | |
dc.identifier.lattes | 4432114051631854 | |
dc.identifier.lattes | 8564043124954667 | |
dc.identifier.uri | http://hdl.handle.net/11449/125811 | |
dc.language.iso | eng | |
dc.relation.ispartof | The Journal of Oral Implantology | |
dc.relation.ispartofjcr | 1.212 | |
dc.relation.ispartofsjr | 0,569 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Currículo Lattes | |
dc.title | Effect of splinting in accuracy of two implants impression techniques | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isDepartmentOfPublication.latestForDiscovery | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.author.lattes | 4432114051631854 | |
unesp.author.lattes | 8564043124954667 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |