Logotipo do repositório
 

Publicação:
Effect of splinting in accuracy of two implants impression techniques

dc.contributor.authorAvila, Érica Dorigatti de [UNESP]
dc.contributor.authorMoraes, Fernanda de Matos [UNESP]
dc.contributor.authorCastanharo, Sabrina Maria [UNESP]
dc.contributor.authorDel´Acqua, Marcelo Antonialli
dc.contributor.authorMollo Júnior, Francisco de Assis [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionCentro Universitário de Araraquara (UNIARA)
dc.date.accessioned2015-08-06T16:13:11Z
dc.date.available2015-08-06T16:13:11Z
dc.date.issued2014
dc.description.abstractBecause there is no consensus in the literature about the need for a splint between copings, the aim of this study was to evaluate, in vitro, the accuracy of 2 impression techniques for implant-supported prostheses. A master cast was fabricated with four parallel implant abutment analogs and a passive framework. Two groups with 5 casts each were formed: Group 1 (squared impression copings with no splint: S) and Group 2 (splinted squared impression copings, using metal drill burs and Pattern resin: SS). The impression material used was polyvinyl siloxane with open trays for standard preparation of the casts. For each cast, the framework was positioned, and a titanium screw was tightened with 10 N·cm torque in analog A, after which measurements of the abutment-framework interface gaps were performed at analogs C and D. This process was repeated for analog D. These measurements were analyzed using software. A one-way analysis of variance (ANOVA) with a confidence interval of 95% was used to analyze the data. Significant differences were detected between S and SS in relation to the master cast (P ≤ 0.05). The median values of the abutment-framework interface gaps were as follows: master cast: 39.64 μm; squared impression copings with no splint: 205.86 μm; splinted squared impression copings: 99.19 μm. Under the limitations of this study, the technique presented for Group 2 produces better results compared with the technique used for Group 1.en
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de Araraquara
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 2009/14882-0
dc.format.extent633-639
dc.identifierhttp://www.joionline.org/doi/full/10.1563/AAID-JOI-D-12-00198?=
dc.identifier.citationThe Journal of Oral Implantology, v. 40, n. 6, p. 633-639, 2014.
dc.identifier.doi10.1563/AAID-JOI-D-12-00198
dc.identifier.issn0160-6972
dc.identifier.lattes4432114051631854
dc.identifier.lattes8564043124954667
dc.identifier.urihttp://hdl.handle.net/11449/125811
dc.language.isoeng
dc.relation.ispartofThe Journal of Oral Implantology
dc.relation.ispartofjcr1.212
dc.relation.ispartofsjr0,569
dc.rights.accessRightsAcesso restritopt
dc.sourceCurrículo Lattes
dc.titleEffect of splinting in accuracy of two implants impression techniquesen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes4432114051631854
unesp.author.lattes8564043124954667
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos