Logotipo do repositório
 

Publicação:
Changes in alveolar bone support induced by the herbst appliance: A tomographic evaluation

dc.contributor.authorSchwartz, João Paulo [UNESP]
dc.contributor.authorRaveli, Taisa Boamorte [UNESP]
dc.contributor.authorSchwartz-Filho, Humberto Osvaldo
dc.contributor.authorRaveli, Dirceu Barnabé [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal do Paraná (UFPR)
dc.date.accessioned2018-12-11T17:28:24Z
dc.date.available2018-12-11T17:28:24Z
dc.date.issued2016-03-01
dc.description.abstractObjective: This study evaluated alveolar bone loss around mandibular incisors, induced by the Herbst appliance. Methods: The sample consisted of 23 patients (11 men, 12 women; mean age of 15.76 ± 1.75 years), Class II, Division 1 malocclusion, treated with the Herbst appliance. CBCT scans were obtained before treatment (T0) and after Herbst treatment (T1). Vertical alveolar bone level and alveolar bone thickness of mandibular incisors were assessed. Buccal (B), lingual (L) and total (T) bone thicknesses were assessed at crestal (1), midroot (2) and apical (3) levels of mandibular incisors. Student’s t-test and Wilcoxon t-test were used to compare dependent samples in parametric and nonparametric cases, respectively. Pearson’s and Spearman’s rank correlation analyses were performed to determine the relationship of changes in alveolar bone thickness. Results were considered at a significance level of 5%. Results: Mandibular incisors showed no statistical significance for vertical alveolar bone level. Alveolar bone thickness of mandibular incisors significantly reduced after treatment at B1, B2, B3, T1 and significantly increased at L2. The magnitude of the statistically significant changes was less than 0.2 mm. The changes in alveolar bone thickness showed no statistical significance with incisor inclination degree. Conclusions: CBCT scans showed an association between the Herbst appliance and alveolar bone loss on the buccal surface of mandibular incisors; however, without clinical significance.en
dc.description.affiliationUniversidade Estadual Paulista (UNESP) Department of Orthodontics
dc.description.affiliationUniversidade Federal do Paraná (UFPR) Department of Stomatology
dc.description.affiliationUnespUniversidade Estadual Paulista (UNESP) Department of Orthodontics
dc.format.extent95-101
dc.identifierhttp://dx.doi.org/10.1590/2177-6709.21.2.095-101.oar
dc.identifier.citationDental Press Journal of Orthodontics, v. 21, n. 2, p. 95-101, 2016.
dc.identifier.doi10.1590/2177-6709.21.2.095-101.oar
dc.identifier.fileS2176-94512016000200095.pdf
dc.identifier.issn2177-6709
dc.identifier.issn2176-9451
dc.identifier.scieloS2176-94512016000200095
dc.identifier.scopus2-s2.0-84973352478
dc.identifier.urihttp://hdl.handle.net/11449/178062
dc.language.isoeng
dc.relation.ispartofDental Press Journal of Orthodontics
dc.relation.ispartofsjr0,489
dc.relation.ispartofsjr0,489
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectActivator appliances
dc.subjectCone-beam computed tomography
dc.subjectPeriodontium
dc.titleChanges in alveolar bone support induced by the herbst appliance: A tomographic evaluationen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentClínica Infantil - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S2176-94512016000200095.pdf
Tamanho:
728.08 KB
Formato:
Adobe Portable Document Format