Logotipo do repositório
 

Publicação:
Influence of Microgap Location and Configuration on Peri-implant Bone Morphology in Nonsubmerged Implants: An Experimental Study in Dogs

dc.contributor.authorWeng, Dietmar
dc.contributor.authorNagata, Maria José Hitomi [UNESP]
dc.contributor.authorBell, Matthias
dc.contributor.authorNascimento de Melo, Luiz Gustavo
dc.contributor.authorBosco, Álvaro Francisco [UNESP]
dc.contributor.institutionUniv Kiel
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:29:39Z
dc.date.accessioned2014-05-20T13:43:23Z
dc.date.available2013-09-30T18:29:39Z
dc.date.available2014-05-20T13:43:23Z
dc.date.issued2010-05-01
dc.description.abstractPurpose: It is unknown whether different micro gap configurations can cause different pen-implant bone reactions. Therefore, this study sought to compare the peri-implant bone morphologies of two implant systems with different implant-abutment connections. Materials and Methods: Three months after mandibular tooth extractions in six mongrel dogs, two oxidized screw implants with an external-hex connection were inserted (hexed group) on one side, whereas on the contralateral side two grit-blasted screw implants with an internal Morse-taper connection (Morse group) were placed. on each side, one implant was inserted level with the bone (equicrestal) and the second implant was inserted 1.5 mm below the bony crest (subcrestal). Healing abutments were inserted immediately after implant placement. Three months later, the peri-implant bone levels, the first bone-to-implant contact points, and the width and steepness of the peri-implant bone defects were evaluated histometrically. Results: All 24 implants osseointegrated clinically and histologically. No statistically significant differences between the hexed group and Morse group were detected for either the vertical position for peri-implant bone levels (Morse equicrestal -0.16 mm, hexed equicrestal -0.22 mm, Morse subcrestal 1.50 mm, hexed subcrestal 0.94 mm) or for the first bone-to-implant contact points (Morse equicrestal -2.08 mm, hexed equicrestal -0.98 mm, Morse subcrestal -1.26 mm, hexed subcrestal -0.76 mm). For the parameters width (Morse equicrestal -0.15 mm, hexed equicrestal -0.59 mm, Morse subcrestal 0.28 mm, hexed subcrestal -0.70 mm) and steepness (Morse equicrestal 25.27 degree, hexed equicrestal 57.21 degree, Morse subcrestal 15.35 degree, hexed subcrestal 37.97 degree) of the pen-implant defect, highly significant differences were noted between the Morse group and the hexed group. Conclusion: Within the limits of this experiment, it can be concluded that different microgap configurations influence the size and shape of the peri-implant bone defect in nonsubmerged implants placed both at the crest and subcrestally. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:540-547en
dc.description.affiliationUniv Kiel, Dept Prosthodont Propaedeut & Dent Mat, Sch Dent, Kiel, Germany
dc.description.affiliationUNESP Univ Estadual Paulista, Div Periodont, Dept Surg & Integrated Clin, Dent Sch Aracatuba, Aracatuba, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Div Periodont, Dept Surg & Integrated Clin, Dent Sch Aracatuba, Aracatuba, Brazil
dc.description.sponsorshipDentsply Friadent
dc.format.extent540-547
dc.identifierhttp://www.quintpub.com/journals/omi/abstract.php?article_id=8096#.Ui9lWcbks_Y
dc.identifier.citationInternational Journal of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 25, n. 3, p. 540-547, 2010.
dc.identifier.issn0882-2786
dc.identifier.lattes8399870097572073
dc.identifier.lattes9831236034935598
dc.identifier.urihttp://hdl.handle.net/11449/15127
dc.identifier.wosWOS:000279356200012
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofInternational Journal of Oral & Maxillofacial Implants
dc.relation.ispartofjcr1.699
dc.relation.ispartofsjr1,576
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectbone morphologyen
dc.subjectequicrestal placementen
dc.subjecthistometric studyen
dc.subjectmicrogapen
dc.subjectsubcrestal placementen
dc.titleInfluence of Microgap Location and Configuration on Peri-implant Bone Morphology in Nonsubmerged Implants: An Experimental Study in Dogsen
dc.typeArtigopt
dcterms.licensehttp://www.quintpub.com/journals/jop/orderreprints.php
dcterms.rightsHolderQuintessence Publishing Co Inc
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes8399870097572073
unesp.author.lattes9831236034935598
unesp.author.orcid0000-0001-5903-5652[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentCirurgia e Clínica Integrada - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: