Publicação: Diametral tensile strength of dual-curing resin cements submitted exclusively to autopolymerization.
dc.contributor.author | Fonseca, Renata Garcia [UNESP] | |
dc.contributor.author | Artusi, Thais Paci [UNESP] | |
dc.contributor.author | Santos, Juliana Gomes dos [UNESP] | |
dc.contributor.author | Adabo, Gelson Luis [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:22:36Z | |
dc.date.available | 2014-05-27T11:22:36Z | |
dc.date.issued | 2007-10-01 | |
dc.description.abstract | OBJECTIVES: To evaluate, at different times, the diametral tensile strength (DTS) of dual-curing resin cements that were not photopolymerized. METHOD AND MATERIALS: Equal amounts of base and catalyst pastes of Panavia F (Kuraray), Variolink II (Vivadent), Rely X (3M ESPE), and Enforce (Dentsply) were mixed and inserted into cylindrical molds (4 x 2 mm) (n = 10). Cements were not photopolymerized. DTS test was performed in a testing machine at 30 minutes, 1 hour, 24 hours, and 7 days. The specimens were stored in light-proof containers with distilled water at 37 degrees C until the time of assay. An autopolymerizing resin cement (Cement-It, Jeneric Pentron) and a zinc phosphate cement served as controls. One-way analysis of variance (ANOVA) and Tukey test were performed separately for each cement and for each time (P <.05). RESULTS: All cements showed an increase in DTS when tested at 1 and 24 hours. Tests at 24 hours and 7 days revealed no statistically significant differences. In all groups, the zinc phosphate cement had the lowest DTS mean values (2.1 MPa, 3.6 MPa, 6.5 MPa, and 6.9 MPa), while Cement-It (35.1 MPa, 33.6 MPa, 46.9 MPa, and 46.3 MPa) and Enforce (31.9 MPa, 31.7 MPa, 43.4 MPa, and 47.6 MPa) presented the highest DTS mean values. CONCLUSION: All cements presented maximal strength at 24 hours. The dual-curing resin cements, even when nonphotopolymerized, demonstrated higher DTS than the zinc phosphate cement and similar or lower values than the autopolymerizing resin cement. | en |
dc.identifier | http://www.quintpub.com/journals/qi/abstract.php?iss2_id=246&article_id=2975 | |
dc.identifier.citation | Quintessence international (Berlin, Germany : 1985), v. 38, n. 9, 2007. | |
dc.identifier.issn | 1936-7163 | |
dc.identifier.lattes | 3041561340615890 | |
dc.identifier.lattes | 2851339311179809 | |
dc.identifier.scopus | 2-s2.0-34848905305 | |
dc.identifier.uri | http://hdl.handle.net/11449/69925 | |
dc.identifier.wos | WOS:000249924600010 | |
dc.language.iso | eng | |
dc.relation.ispartof | Quintessence international (Berlin, Germany : 1985) | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | resin cement | |
dc.subject | analysis of variance | |
dc.subject | chemistry | |
dc.subject | comparative study | |
dc.subject | dental bonding | |
dc.subject | dental care | |
dc.subject | evaluation | |
dc.subject | nonparametric test | |
dc.subject | phase transition | |
dc.subject | tensile strength | |
dc.subject | time | |
dc.subject | Analysis of Variance | |
dc.subject | Dental Bonding | |
dc.subject | Dental Stress Analysis | |
dc.subject | Phase Transition | |
dc.subject | Resin Cements | |
dc.subject | Statistics, Nonparametric | |
dc.subject | Tensile Strength | |
dc.subject | Time Factors | |
dc.title | Diametral tensile strength of dual-curing resin cements submitted exclusively to autopolymerization. | en |
dc.type | Artigo | pt |
dcterms.license | http://www.quintpub.com/terms.php | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isDepartmentOfPublication.latestForDiscovery | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.author.lattes | 3041561340615890 | |
unesp.author.lattes | 2851339311179809 | |
unesp.author.orcid | 0000-0002-0734-7926[4] | |
unesp.author.orcid | 0000-0001-6657-913X[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |