Logotipo do repositório
 

Publicação:
Comparison of the osseointegration of implants placed in areas grafted with HA/TCP and native bone

dc.contributor.authorLima, Julia Raulino
dc.contributor.authorSoares, Priscilla Barbosa Ferreira
dc.contributor.authorPinotti, Felipe Eduardo [UNESP]
dc.contributor.authorMarcantonio, Rosemary Adriana Chiérici [UNESP]
dc.contributor.authorMarcantonio-Junior, Elcio [UNESP]
dc.contributor.authorde Oliveira, Guilherme José Pimentel Lopes
dc.contributor.institutionUniversidade Federal de Uberlândia (UFU)
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-05-01T16:48:41Z
dc.date.available2022-05-01T16:48:41Z
dc.date.issued2022-01-01
dc.description.abstractThis study evaluated the osseointegration of implants in areas grafted with biphasic ceramic based on hydroxyapatite/β-tricalcium phosphate (HA/TCP) and in native bone (NB). Twenty-eight rats were randomly assigned into two groups of 14 animals each: HA/TCP group: implants installed in areas grafted with HA/TCP and NB group: implants installed in areas of native bone. Bone defects were made in both tibiae of the rats belonging to the HA/TCP group and then filled with this bone substitute. After 60 days, the rats were submitted to surgical procedures for implant placement in grafted areas in both tibiae in the HA/TCP group while the implants were installed directly in native bone in the NB group. The animals were euthanized 15 and 45 days, respectively, after the implant placement. Biomechanical (removal torque), microtomographic (volume of mineralized tissues around the implants), and histomorphometric (Bone-Implant contact—%BIC and bone area between the implant threads—%BBT) analyzes were conducted to assess the osseointegration process. The HA/TCP group showed lower values of removal torque, volume of mineralized tissue around the implants, lower %BIC, and %BBT compared to the NB group in both experimental periods. Osseointegration of implants placed in grafted areas with HA/TCP was lower compared to the osseointegration observed in native bone areas.en
dc.description.affiliationDepartment of Periodontology/Implantology Universidade Federal de Uberlândia – UFU School of Dentistry, MG
dc.description.affiliationDepartment of Diagnosis and Surgery Universidade Estadual Paulista – UNESP School of Dentistry, SP
dc.description.affiliationUnespDepartment of Diagnosis and Surgery Universidade Estadual Paulista – UNESP School of Dentistry, SP
dc.identifierhttp://dx.doi.org/10.1002/jemt.24126
dc.identifier.citationMicroscopy Research and Technique.
dc.identifier.doi10.1002/jemt.24126
dc.identifier.issn1097-0029
dc.identifier.issn1059-910X
dc.identifier.scopus2-s2.0-85127676208
dc.identifier.urihttp://hdl.handle.net/11449/234363
dc.language.isoeng
dc.relation.ispartofMicroscopy Research and Technique
dc.sourceScopus
dc.subjectbone substitutes
dc.subjectdental implants
dc.subjectosseointegration
dc.titleComparison of the osseointegration of implants placed in areas grafted with HA/TCP and native boneen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.orcid0000-0002-6824-4904[1]
unesp.author.orcid0000-0002-4492-8957[2]
unesp.author.orcid0000-0002-1555-6242[3]
unesp.author.orcid0000-0002-5052-7439[4]
unesp.author.orcid0000-0003-1294-2305[5]
unesp.author.orcid0000-0001-8778-0115[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos