Logotipo do repositório
 

Publicação:
Effectiveness of sealing gel on vertical misfit at the implant-abutment interface and preload maintenance of screw-retained implant-supported prostheses

dc.contributor.authorSeloto, Camila Berbel [UNESP]
dc.contributor.authorStrazzi-Sahyon, Henrico Badaoui [UNESP]
dc.contributor.authordos Santos, Paulo Henrique [UNESP]
dc.contributor.authorAssunção, Wirley Gonçalves [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-12-12T02:08:23Z
dc.date.available2020-12-12T02:08:23Z
dc.date.issued2020-01-01
dc.description.abstractPurpose: This in vitro study evaluated the effectiveness of a sealing agent on v: ertical misfit of the implant-abutment interface in an external hexagon implant system before and after mechanical cyclic loading. Effects on preload maintenance of retaining screws after mechanical cycling were also assessed. Materials and Methods: External hexagon implant systems were divided into two groups (n = 12) according to the presence of an anaerobic sealing gel (control group-no sealing gel; experimental group-sealing gel applied). A prefabricated UCLA abutment was attached to the external hexagon implant with a digital torque wrench in accordance with the recommendations of the manufacturer. Specimens were tested through mechanical cyclic loading (1 × 106 cycles, 2 Hz, and 130 N). Vertical misfit of the implant-abutment interface was analyzed using a stereomicroscope, and reverse torque values were obtained using a digital wrench. Misfit and reverse torque data were measured and analyzed via analysis of variance (ANOVA) and the Tukey least significant difference test (α = .05). Results: The sealing gel promoted lower vertical misfit values in the test group after mechanical cycling compared with before cycling (P = .009). The control group showed lower reverse torque values for retaining screws compared with the initial torque after mechanical cyclic loading (P < .0001). However, sealing gel application promoted higher reverse torque values in the test group postcycling (P = .0003). Conclusion: Anaerobic sealing agent application improved vertical misfit of the implant-abutment interface and preload maintenance of screw-retained implant-supported prostheses post- mechanical cycling.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araçatuba School of Dentistry São Paulo State University (UNESP)
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araçatuba School of Dentistry São Paulo State University (UNESP)
dc.format.extent479-484
dc.identifierhttp://dx.doi.org/10.11607/jomi.7978
dc.identifier.citationInternational Journal of Oral and Maxillofacial Implants, v. 35, n. 3, p. 479-484, 2020.
dc.identifier.doi10.11607/jomi.7978
dc.identifier.issn1942-4434
dc.identifier.issn0882-2786
dc.identifier.scopus2-s2.0-85085264293
dc.identifier.urihttp://hdl.handle.net/11449/200505
dc.language.isoeng
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Implants
dc.sourceScopus
dc.subjectAbutment
dc.subjectImplant-supported prosthesis
dc.subjectPreload
dc.subjectScrew
dc.titleEffectiveness of sealing gel on vertical misfit at the implant-abutment interface and preload maintenance of screw-retained implant-supported prosthesesen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt