Comparative Analysis of 2 Techniques of Double-Gloving Protection During Arch Bar Placement for Intermaxillary Fixation
Carregando...
Fontes externas
Fontes externas
Data
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Elsevier
Tipo
Artigo
Direito de acesso
Acesso restrito
Fontes externas
Fontes externas
Resumo
Purpose: This study was conducted to comparatively evaluate, in a prospective and randomized manner, 2 techniques for providing double-gloving protection during arch bar placement for intermaxillary fixation. Materials and Methods: A total of 42 consecutive patients in whom application of an Erich bar was indicated for intermaxillary fixation were equally divided into 2 groups. In group 1, 2 sterile surgical gloves were used; in group 2, a nonsterile disposable inner glove was used under a sterile surgical glove. Wilcoxon, Mann-Whitney, Kruskal-Wallis, and binomial statistical tests were used to analyze the findings. Results: A total of 103 perforations were found in the outer gloves (47 in group 1 and 56 in group 2), along with 5 perforations in inner gloves in both groups (α = .01). No significant statistical difference was found between groups in terms of inner glove perforations (α = .05). The nondominant hand presented with 70.9% of the perforations, statistically significant to 1%. Conclusions: Both double-gloving techniques were found to provide effective clinician protection. The use of a nonsterile disposable glove under the surgical glove is possible for less-invasive procedures, offering the same safety as using 2 sterile surgical gloves while decreasing operational costs. This method does not eliminate the need to change gloves when a perforation is suspected or noted during the surgery, however. © 2007 American Association of Oral and Maxillofacial Surgeons.
Descrição
Palavras-chave
alveolar bone , arch bar placement , clinical trial , controlled clinical trial , cost control , disposable equipment , double gloving technique , equipment design , glove perforation , iatrogenic disease , instrument sterilization , intermaxillary fixation , minimally invasive surgery , prospective study , protective equipment , randomized controlled trial , statistical analysis , surgical glove , surgical technique , Disease Transmission, Patient-to-Professional , Disease Transmission, Professional-to-Patient , Equipment Failure , Fracture Fixation, Internal , Gloves, Surgical , Infection Control , Maxilla , Motor Skills , Oral Surgical Procedures , Prospective Studies , Statistics, Nonparametric , Wounds, Stab
Idioma
Inglês
Citação
Journal of Oral and Maxillofacial Surgery, v. 65, n. 10, p. 1922-1925, 2007.