Pulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tips

dc.contributor.authorMollica, Fernanda Brandao [UNESP]
dc.contributor.authorCamargo, Fernanda Pelogia [UNESP]
dc.contributor.authorZamboni, Sandra Costa [UNESP]
dc.contributor.authorBraga Pereira, Sarina Maciel [UNESP]
dc.contributor.authorTeixeira, Symone Cristina [UNESP]
dc.contributor.authorNogueira Junior, Lafayette [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T14:04:59Z
dc.date.available2014-05-20T14:04:59Z
dc.date.issued2008-05-01
dc.description.abstractThe aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.en
dc.description.affiliationSão Paulo State Univ, Dept Restorat Dent, São Paulo, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Pediat Dent, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Restorat Dent, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Pediat Dent, São Paulo, Brazil
dc.format.extent209-213
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572008000300009
dc.identifier.citationJournal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 16, n. 3, p. 209-213, 2008.
dc.identifier.fileS1678-77572008000300009.pdf
dc.identifier.issn1678-7757
dc.identifier.lattes1728462753516751
dc.identifier.lattes7376974788169619
dc.identifier.scieloS1678-77572008000300009
dc.identifier.urihttp://hdl.handle.net/11449/22788
dc.identifier.wosWOS:000256795900009
dc.language.isoeng
dc.publisherUniversidade de São Paulo (USP), Faculdade de Odontologia de Bauru
dc.relation.ispartofJournal of Applied Oral Science
dc.relation.ispartofjcr1.709
dc.relation.ispartofsjr0,645
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectdental pulpen
dc.subjectdental cavity preparationen
dc.titlePulpal temperature increase with high-speed handpiece, ER : YAG laser and ultrasound tipsen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/jaos/paboutj.htm
dcterms.rightsHolderUniv São Paulo Fac Odontologia Bauru
dspace.entity.typePublication
unesp.author.lattes1728462753516751
unesp.author.lattes7376974788169619
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt
unesp.departmentOdontologia Social e Clínica Infantil - ICTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1678-77572008000300009.pdf
Tamanho:
271.95 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: