Logotipo do repositório
 

Publicação:
A method for the geometric standardization of intraoral radiographs for long-term follow up of replanted teeth: A case report

dc.contributor.authorHamanaka, Elizane Ferreira [UNESP]
dc.contributor.authorPoi, Wilson Roberto [UNESP]
dc.contributor.authorSalzedas, Leda Maria Pescinini [UNESP]
dc.contributor.authorAlves, Lucieni Campoli [UNESP]
dc.contributor.authorBarioni, Sônia Regina Panzarini [UNESP]
dc.contributor.authorSonoda, Celso Koogi [UNESP]
dc.contributor.authorMartins, Christine Men [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:28:46Z
dc.date.available2014-05-27T11:28:46Z
dc.date.issued2013-04-01
dc.description.abstractThe interpretation of the set of radiographs taken during the follow-up period after tooth replantation might pose several difficulties, especially the inability to adequately reproduce the projection geometry of the exposures. This article describes a method for the geometric standardization of intraoral radiographs using a custom-made apparatus comprising a film-holder attached to an occlusal splint for the long-term follow up of dentoalveolar trauma. The method was applied in a patient who suffered an avulsion of the maxillary central incisors and had the teeth replanted after 4 h in saline storage. Endodontic treatment started 7 days after the trauma with changes of a calcium hydroxide intracanal medication every 15 days in the first 2 months and thereafter at 30-day intervals for 8 months. Root canal filling was carried out after this period. The radiographic exposures taken at the follow-up visits were standardized to identify the possible alterations during the repair process, such as root resorptions. A maxillary arch impression was made with alginate, and the model was cast in stone for fabrication of an acetate occlusal splint. The custom-made apparatus used for standardization of the radiographic exposures was fabricated by fixing a Rinn X-C-P film-holder and a 5-mm-long piece of 0.7-mm orthodontic wire to the occlusal splint with autopolymerized acrylic resin. Radiographs were taken at 4-month intervals, starting 10 months after replantation up to 76 months. The images were digitized and analysed using the Digora system. The length of the central incisors was determined to verify the reproduction of the projection geometry of the exposures and the orthodontic wire served to assess accuracy during length estimations in the radiographs. The method described in this article for geometric standardization of intraoral radiographs provided a consistent reproduction of the geometric exposure parameters, being indicated for use in the radiographic follow up of cases of dentoalveolar trauma. © 2012 John Wiley & Sons A/S.en
dc.description.affiliationDepartment of Surgery and Integrated Clinics School of Dentistry of Araçatuba, São Paulo State University (UNESP), Araçatuba, SP
dc.description.affiliationUnespDepartment of Surgery and Integrated Clinics School of Dentistry of Araçatuba, São Paulo State University (UNESP), Araçatuba, SP
dc.format.extent121-126
dc.identifierhttp://dx.doi.org/10.1111/j.1600-9657.2012.01145.x
dc.identifier.citationDental Traumatology, v. 29, n. 2, p. 121-126, 2013.
dc.identifier.doi10.1111/j.1600-9657.2012.01145.x
dc.identifier.issn1600-4469
dc.identifier.issn1600-9657
dc.identifier.lattes4185776888167996
dc.identifier.lattes9653292815706560
dc.identifier.lattes5691730284259344
dc.identifier.lattes5007703439443544
dc.identifier.orcid0000-0001-9017-0473
dc.identifier.scopus2-s2.0-84874668448
dc.identifier.urihttp://hdl.handle.net/11449/74974
dc.identifier.wosWOS:000315743900008
dc.language.isoeng
dc.relation.ispartofDental Traumatology
dc.relation.ispartofjcr1.414
dc.relation.ispartofsjr0,724
dc.relation.ispartofsjr0,724
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.subjectDentoalveolar trauma
dc.subjectRadiographic standardization
dc.subjectTooth avulsion
dc.subjectTooth replantation
dc.titleA method for the geometric standardization of intraoral radiographs for long-term follow up of replanted teeth: A case reporten
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes4185776888167996
unesp.author.lattes9653292815706560
unesp.author.lattes5691730284259344
unesp.author.lattes5007703439443544
unesp.author.orcid0000-0001-9017-0473[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentCirurgia e Clínica Integrada - FOApt

Arquivos