Characterization of Five Different Implant Surfaces and Their Effect on Osseointegration: A Study in Dogs

dc.contributor.authorCoelho, Paulo G.
dc.contributor.authorBonfante, Estevam A.
dc.contributor.authorPessoa, Roberto S. [UNESP]
dc.contributor.authorMarin, Charles
dc.contributor.authorGranato, Rodrigo
dc.contributor.authorGiro, Gabriela [UNESP]
dc.contributor.authorWitek, Lukasz
dc.contributor.authorSuzuki, Marcelo
dc.contributor.institutionNYU
dc.contributor.institutionUNIGRANRIO Univ Sch Hlth Sci
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)
dc.contributor.institutionTufts Univ
dc.date.accessioned2013-09-30T18:32:01Z
dc.date.accessioned2014-05-20T13:45:30Z
dc.date.available2013-09-30T18:32:01Z
dc.date.available2014-05-20T13:45:30Z
dc.date.issued2011-05-01
dc.description.abstractBackground: Chemical modification of implant surface is typically associated with surface topographic alterations that may affect early osseointegration. This study investigates the effects of controlled surface alterations in early osseointegration in an animal model.Methods: Five implant surfaces were evaluated: 1) alumina-blasting, 2) biologic blasting, 3) plasma, 4) microblasted resorbable blasting media (microblasted RBM), and 5) alumina-blasting/acid-etched (AB/AE). Surface topography was characterized by scanning electron microscopy and optical interferometry, and chemical assessment by x-ray photoelectron spectroscopy. The implants were placed in the radius of six dogs, remaining 2 and 4 weeks in vivo. After euthanization, specimens were torqued-to-interface failure and non-decalcified - processed for histomorphologic bone-implant contact, and bone area fraction-occupied evaluation. Statistical evaluation was performed by one-way analysis of variance (P < 0.05) and post hoc testing by the Tukey test.Results: The alumina-blasting surface presented the highest average surface roughness and mean root square of the surface values, the biologic blasting the lowest, and AB/AE an intermediate value. The remaining surfaces presented intermediate values between the biologic blasting and AB/AE. The x-ray photoelectron spectroscopy spectra revealed calcium and phosphorus for the biologic blasting and microblasted RBM surfaces, and the highest oxygen levels for the plasma, microblasted RBM, and AB/AE surfaces. Significantly higher torque was observed at 2 weeks for the microblasted RBM surface (P < 0.04), but no differences existed between surfaces at 4 weeks (P > 0.74). No significant differences in bone-implant contact and bone area fraction-occupied values were observed at 2 and 4 weeks.Conclusion: The five surfaces were osteoconductive and resulted in high degrees of osseointegration and biomechanical fixation. J Periodontol 2011;82:742-750.en
dc.description.affiliationNYU, Dept Biomat & Biomimet, New York, NY USA
dc.description.affiliationUNIGRANRIO Univ Sch Hlth Sci, Postgrad Program Dent, Duque de Caxias, RJ, Brazil
dc.description.affiliationUniv Estadual Paulista, Fac Odontol Araraquara, Dept Oral Diag & Surg, Araraquara, SP, Brazil
dc.description.affiliationUniversidade Federal de Santa Catarina (UFSC), Dept Dent, Florianopolis, SC, Brazil
dc.description.affiliationTufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
dc.description.affiliationUnespUniv Estadual Paulista, Fac Odontol Araraquara, Dept Oral Diag & Surg, Araraquara, SP, Brazil
dc.format.extent742-750
dc.identifierhttp://dx.doi.org/10.1902/jop.2010.100520
dc.identifier.citationJournal of Periodontology. Chicago: Amer Acad Periodontology, v. 82, n. 5, p. 742-750, 2011.
dc.identifier.doi10.1902/jop.2010.100520
dc.identifier.issn0022-3492
dc.identifier.urihttp://hdl.handle.net/11449/16015
dc.identifier.wosWOS:000290414700013
dc.language.isoeng
dc.publisherAmer Acad Periodontology
dc.relation.ispartofJournal of Periodontology
dc.relation.ispartofjcr3.392
dc.relation.ispartofsjr1,408
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectAnimalen
dc.subjectboneen
dc.subjectdental implanten
dc.subjecthistologyen
dc.subjectosseointegrationen
dc.subjecttorqueen
dc.titleCharacterization of Five Different Implant Surfaces and Their Effect on Osseointegration: A Study in Dogsen
dc.typeArtigopt
dcterms.licensehttp://www.joponline.org/page/permissionRequests.jsp
dcterms.rightsHolderAmer Acad Periodontology
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.orcid0000-0002-7590-8158[6]
unesp.author.orcid0000-0001-6867-8350[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: