Logotipo do repositório
 

Publicação:
A Thermal Investigation of Dental Bleaching In Vitro

dc.contributor.authorKabbach, William [UNESP]
dc.contributor.authorZezell, Denise Maria
dc.contributor.authorPereira, Thiago Martini
dc.contributor.authorAlbero, Felipe Guimaraes
dc.contributor.authorClavijo, Victor Rene Grover [UNESP]
dc.contributor.authorAndrade, Marcelo Ferrarezi de [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionInst Nucl Energy Res
dc.date.accessioned2014-05-20T13:47:14Z
dc.date.available2014-05-20T13:47:14Z
dc.date.issued2008-10-01
dc.description.abstractObjective: Our goal was to investigate the surface temperature variations in the cervical region via infrared thermography, as well as the temperature within the pulp chamber via thermocouples, of mandibular incisors when subjected to dental bleaching using two different 35% hydrogen peroxide gels, red (HP) and green (HPM), when activated by halogen light (HL) and LED light.Background Data: Temperatures increases of more than 5.5 degrees C are considered to be potentially threatening to pulp vitality, while those higher than 10 degrees C can result in periodontal injury.Materials and Methods: Tooth samples were randomly divided into four groups (n = 10 each), according to the bleaching agent and catalyst light source used.Results: Mean values and standard deviations of the temperature increases inside the pulp chamber in the HL groups were 4.4 degrees +/- 2.1 degrees C with HP, and 4.5 degrees +/- 1.2 degrees C with HPM; whereas in the groups using LED light, they were 1.4 degrees +/- 0.3 degrees C for HP, and 1.5 degrees +/- 0.2 degrees C for HPM. For the root surfaces, the maximum temperature increases in the groups irradiated with HL were 6.5 degrees +/- 1.5 degrees C for HP, and 7.5 degrees +/- 1.1 degrees C with HPM; whereas in the groups irradiated with LED light, they were 2.8 degrees +/- 0.7 degrees C with HP, and 3 degrees +/- 0.8 degrees C with HPM. There were no statistically significant differences in pulp and surface temperature increases between the groups using different gels, although the mean temperature increases were significantly higher for the groups irradiated with HL when compared with those irradiated with the LED light (p < 0.05 with Tukey's test).Conclusion: LED light may be safe for periodontal and pulp tissue when using this method, but HL should be used with care.en
dc.description.affiliationUniv Estadual Paulista, Dept Restorat Dent, Araraquara, Brazil
dc.description.affiliationInst Nucl Energy Res, Laser & Applicat Ctr, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Restorat Dent, Araraquara, Brazil
dc.format.extent489-493
dc.identifierhttp://dx.doi.org/10.1089/pho.2007.2221
dc.identifier.citationPhotomedicine and Laser Surgery. New Rochelle: Mary Ann Liebert Inc., v. 26, n. 5, p. 489-493, 2008.
dc.identifier.doi10.1089/pho.2007.2221
dc.identifier.fileWOS000260503600013.pdf
dc.identifier.issn1549-5418
dc.identifier.lattes2897622509429759
dc.identifier.urihttp://hdl.handle.net/11449/16780
dc.identifier.wosWOS:000260503600013
dc.language.isoeng
dc.publisherMary Ann Liebert, Inc.
dc.relation.ispartofPhotomedicine and Laser Surgery
dc.relation.ispartofjcr1.620
dc.relation.ispartofsjr0,443
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.titleA Thermal Investigation of Dental Bleaching In Vitroen
dc.typeArtigo
dcterms.licensehttp://www.liebertpub.com/archpolicy/journal-of-womens-health/42/
dcterms.rightsHolderMary Ann Liebert Inc.
dspace.entity.typePublication
unesp.author.lattes2897622509429759
unesp.author.orcid0000-0001-7404-9606[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
WOS000260503600013.pdf
Tamanho:
889.96 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: