Determination of salicylate in blood serum using an amperometric biosensor based on salicylate hydroxylase immobilized in a polypyrrole-glutaraldehyde matrix

dc.contributor.authorRover Júnior, Laércio
dc.contributor.authorOliveira Neto, Graciliano de
dc.contributor.authorFernandes, João Roberto [UNESP]
dc.contributor.authorKubota, Lauro Tatsuo
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade São Francisco (USF)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:26:46Z
dc.date.available2014-05-20T13:26:46Z
dc.date.issued2000-03-06
dc.description.abstractThe use of an amperometric biosensor for the salicylate determination in blood serum is described. The biosensor is based on salicylate hydroxylase (EC 1.14.13.1) electropolymerized onto a glassy carbon-working electrode with polypyrrole and glutaraldehyde, to improve the biosensor lifetime. The hexacyanoferrate (II) was also incorporated to work as a redox mediator to minimize possible interferences. The salicylate is enzymatically converted to catechol, which is monitored amperometrically by its electrooxidation at +0.170 V versus SCE (saturated calomel electrode). Salicylate determination was carried out maintaining the ratio between β-NADH and salicylate at 4:1 (30°C). The amperometric response of the biosensor was linearly proportional to the salicylate concentration between 2.3 x 10-6 and 1.4 x 10-5 mol l- 1, in 0.1 mol l-1 phosphate buffer (pH 7.8), containing 0.1 mol l-1 KCl and 5.0 x 10-4 mol l-1 Na2H2EDTA, as supporting electrolyte. The recovery studies, in the presence of several interfering compounds, showed recoveries between 96.4 and 104.8%. The useful lifetime of the biosensor in the concentration range evaluated was at least 40 days, in continuous use. Blood serum samples analyzed by this biosensor showed a good correlation compared to the spectrophotometric method (Trinder) used as reference, presenting relative deviations lower than 7.0%. (C) 2000 Elsevier Science B.V.en
dc.description.affiliationUniv Sao Francisco, Fac Ciências Farmaceut, BR-12900000 Braganca Paulista, SP, Brazil
dc.description.affiliationUNICAMP, Inst Quim, BR-13083970 Campinas, SP, Brazil
dc.description.affiliationUNESP, Dept Quim, FC, BR-17033360 Bauru, SP, Brazil
dc.description.affiliationUnespDepto. de Química-FC/UNESP 17033-360, SP, Bauru
dc.format.extent547-557
dc.identifierhttp://dx.doi.org/10.1016/S0039-9140(99)00311-2
dc.identifier.citationTalanta. Amsterdam: Elsevier B.V., v. 51, n. 3, p. 547-557, 2000.
dc.identifier.doi10.1016/S0039-9140(99)00311-2
dc.identifier.issn0039-9140
dc.identifier.lattes8540599256820672
dc.identifier.scopus2-s2.0-0342905042
dc.identifier.urihttp://hdl.handle.net/11449/130628
dc.identifier.wosWOS:000085712300014
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofTalanta
dc.relation.ispartofjcr4.244
dc.relation.ispartofsjr1,186
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectPolypyrrole
dc.subjectSalicylate determination
dc.subjectSalicylate hydroxylase
dc.subjectSerum samples
dc.subjectBuffer
dc.subjectCarbon
dc.subjectCatechol
dc.subjectElectrolyte
dc.subjectFerrocyanide
dc.subjectGlutaraldehyde
dc.subjectMercurous chloride
dc.subjectOxygenase
dc.subjectPhosphate
dc.subjectPolypyrrole
dc.subjectReduced nicotinamide adenine dinucleotide
dc.subjectSalicylic acid
dc.subjectAmperometry
dc.subjectBiosensor
dc.subjectBlood analysis
dc.subjectChemical composition
dc.subjectControlled study
dc.subjectDrug determination
dc.subjectElectrode
dc.subjectIntermethod comparison
dc.subjectOxidation
dc.subjectpH
dc.subjectPolymerization
dc.subjectSerum
dc.subjectSpectrophotometry
dc.subjectTemperature
dc.titleDetermination of salicylate in blood serum using an amperometric biosensor based on salicylate hydroxylase immobilized in a polypyrrole-glutaraldehyde matrixen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.lattes8540599256820672
unesp.author.orcid0000-0001-8189-2618[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências, Baurupt
unesp.departmentQuímica - FCpt

Arquivos