Publicação: Determination of salicylate in blood serum using an amperometric biosensor based on salicylate hydroxylase immobilized in a polypyrrole-glutaraldehyde matrix
dc.contributor.author | Rover Júnior, Laércio | |
dc.contributor.author | Oliveira Neto, Graciliano de | |
dc.contributor.author | Fernandes, João Roberto [UNESP] | |
dc.contributor.author | Kubota, Lauro Tatsuo | |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
dc.contributor.institution | Universidade São Francisco (USF) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:26:46Z | |
dc.date.available | 2014-05-20T13:26:46Z | |
dc.date.issued | 2000-03-06 | |
dc.description.abstract | The use of an amperometric biosensor for the salicylate determination in blood serum is described. The biosensor is based on salicylate hydroxylase (EC 1.14.13.1) electropolymerized onto a glassy carbon-working electrode with polypyrrole and glutaraldehyde, to improve the biosensor lifetime. The hexacyanoferrate (II) was also incorporated to work as a redox mediator to minimize possible interferences. The salicylate is enzymatically converted to catechol, which is monitored amperometrically by its electrooxidation at +0.170 V versus SCE (saturated calomel electrode). Salicylate determination was carried out maintaining the ratio between β-NADH and salicylate at 4:1 (30°C). The amperometric response of the biosensor was linearly proportional to the salicylate concentration between 2.3 x 10-6 and 1.4 x 10-5 mol l- 1, in 0.1 mol l-1 phosphate buffer (pH 7.8), containing 0.1 mol l-1 KCl and 5.0 x 10-4 mol l-1 Na2H2EDTA, as supporting electrolyte. The recovery studies, in the presence of several interfering compounds, showed recoveries between 96.4 and 104.8%. The useful lifetime of the biosensor in the concentration range evaluated was at least 40 days, in continuous use. Blood serum samples analyzed by this biosensor showed a good correlation compared to the spectrophotometric method (Trinder) used as reference, presenting relative deviations lower than 7.0%. (C) 2000 Elsevier Science B.V. | en |
dc.description.affiliation | Univ Sao Francisco, Fac Ciências Farmaceut, BR-12900000 Braganca Paulista, SP, Brazil | |
dc.description.affiliation | UNICAMP, Inst Quim, BR-13083970 Campinas, SP, Brazil | |
dc.description.affiliation | UNESP, Dept Quim, FC, BR-17033360 Bauru, SP, Brazil | |
dc.description.affiliationUnesp | Depto. de Química-FC/UNESP 17033-360, SP, Bauru | |
dc.format.extent | 547-557 | |
dc.identifier | http://dx.doi.org/10.1016/S0039-9140(99)00311-2 | |
dc.identifier.citation | Talanta. Amsterdam: Elsevier B.V., v. 51, n. 3, p. 547-557, 2000. | |
dc.identifier.doi | 10.1016/S0039-9140(99)00311-2 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.lattes | 8540599256820672 | |
dc.identifier.scopus | 2-s2.0-0342905042 | |
dc.identifier.uri | http://hdl.handle.net/11449/130628 | |
dc.identifier.wos | WOS:000085712300014 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Talanta | |
dc.relation.ispartofjcr | 4.244 | |
dc.relation.ispartofsjr | 1,186 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Polypyrrole | |
dc.subject | Salicylate determination | |
dc.subject | Salicylate hydroxylase | |
dc.subject | Serum samples | |
dc.subject | Buffer | |
dc.subject | Carbon | |
dc.subject | Catechol | |
dc.subject | Electrolyte | |
dc.subject | Ferrocyanide | |
dc.subject | Glutaraldehyde | |
dc.subject | Mercurous chloride | |
dc.subject | Oxygenase | |
dc.subject | Phosphate | |
dc.subject | Polypyrrole | |
dc.subject | Reduced nicotinamide adenine dinucleotide | |
dc.subject | Salicylic acid | |
dc.subject | Amperometry | |
dc.subject | Biosensor | |
dc.subject | Blood analysis | |
dc.subject | Chemical composition | |
dc.subject | Controlled study | |
dc.subject | Drug determination | |
dc.subject | Electrode | |
dc.subject | Intermethod comparison | |
dc.subject | Oxidation | |
dc.subject | pH | |
dc.subject | Polymerization | |
dc.subject | Serum | |
dc.subject | Spectrophotometry | |
dc.subject | Temperature | |
dc.title | Determination of salicylate in blood serum using an amperometric biosensor based on salicylate hydroxylase immobilized in a polypyrrole-glutaraldehyde matrix | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.lattes | 8540599256820672 | |
unesp.author.orcid | 0000-0001-8189-2618[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Ciências, Bauru | pt |
unesp.department | Química - FC | pt |