Publicação: Effect of cooling procedure on final denture base adaptation
dc.contributor.author | Ganzarolli, S. M. | |
dc.contributor.author | Rached, R. N. | |
dc.contributor.author | Garcia, RCMR | |
dc.contributor.author | Del Bel Cury, A. A. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Pontifícia Universidade Católica do Paraná (PUCPR) | |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
dc.date.accessioned | 2014-05-20T15:24:10Z | |
dc.date.available | 2014-05-20T15:24:10Z | |
dc.date.issued | 2002-08-01 | |
dc.description.abstract | Well-fitted dentures prevent hyperplasic lesions, provide chewing efficiency and promote patient's comfort. Several factors may affect final adaptation of dentures, as the type of the acrylic resin, the flask cooling procedure and the water uptake. This investigation evaluated the effect of water storage and two different cooling procedures [bench cooling (BC) for 2 h; running water (RW) at 20 degreesC for 45 min] on the final adaptation of denture bases. A heat-cured acrylic resin (CL, Classico, Classico Artigos Odontologicos) and two microwave-cured acrylic resins [Acron MC, (AC) GC Dent. Ind. Corp.; Onda Cryl (OC), Classico Artigos Odontologicos] were used to make the bases. Adaptation was assessed by measuring the weight of an intervening layer of silicone impression material between the base and the master die. Data was submitted to ANOVA and Tukey's test (0.05). The following means were found: (BC) CL=0.72 +/- 0.03 a; AC=0.70 +/- 0.03 b; OC=0.76 +/- 0.04 c//(RW) CL= 1.00 +/- 0.11 a; AC=1.00 +/- 0.12 a; OC=0.95 +/- 0.10 a. Different labels join groups that are not statistically different (P > 0.05). Comparisons are made among groups submitted to the same cooling procedure (BC or RW). The conclusions are: interaction of type of material and cooling procedure had a statistically significant effect on the final adaptation of the denture bases (P < 0.05); water storage was not detected as a source of variance (P > 0.05) on the final adaptation. | en |
dc.description.affiliation | Univ Estadual Paulista, Sch Hlth Sci, São Paulo, Brazil | |
dc.description.affiliation | Pontifical Catholic Univ Parana, Sch Dent, Curitiba, Parana, Brazil | |
dc.description.affiliation | Univ Campinas, Piracicaba Dent Sch, São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Sch Hlth Sci, São Paulo, Brazil | |
dc.format.extent | 787-790 | |
dc.identifier | http://dx.doi.org/10.1046/j.1365-2842.2002.00886.x | |
dc.identifier.citation | Journal of Oral Rehabilitation. Oxford: Blackwell Publishing Ltd, v. 29, n. 8, p. 787-790, 2002. | |
dc.identifier.doi | 10.1046/j.1365-2842.2002.00886.x | |
dc.identifier.issn | 0305-182X | |
dc.identifier.uri | http://hdl.handle.net/11449/34816 | |
dc.identifier.wos | WOS:000177951200013 | |
dc.language.iso | eng | |
dc.publisher | Blackwell Publishing | |
dc.relation.ispartof | Journal of Oral Rehabilitation | |
dc.relation.ispartofjcr | 2.051 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | cooling | pt |
dc.subject | denture | pt |
dc.subject | acrylic resin | pt |
dc.subject | microwave | pt |
dc.subject | heat and adaptation | pt |
dc.title | Effect of cooling procedure on final denture base adaptation | en |
dc.type | Artigo | |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Blackwell Publishing Ltd | |
dspace.entity.type | Publication |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: