Repository logo

Laser Ablation of Benign Thyroid Nodules: A Prospective Pilot Study With a Preliminary Analysis of the Employed Energy

Loading...
Thumbnail Image

Authors

Costa de Freitas, Ricardo Miguel
Miazaki, Aline Paterno
Tsunemi, Miriam Harumi
Furtado de Araujo Filho, Vergilius Jose
Marui, Suemi
Seguro Danilovic, Debora Lucia
Buchpiguel, Carlos Alberto
Chammas, Maria Cristina

Advisor

Coadvisor

Graduate program

Undergraduate course

Journal Title

Journal ISSN

Volume Title

Publisher

Wiley-Blackwell

Type

Article

Access right

Acesso restrito

Abstract

Background and Objectives To assess the effectiveness of ultrasound (US)-guided laser ablation of benign thyroid nodules (TNs) under different amounts of applied energy. Study Design/Materials and Methods Thirty-four euthyroid patients with 5-18 ml TNs were enrolled: 21 (laser ablation) and 13 (clinical follow up) patients with a mean age of 56.2 +/- 12.0 and 54.7 +/- 14.7 years, respectively. The laser ablation protocol used a 1.064 mm wavelength diode laser source; 3.5 W output power; 1,100-1,500 J and 5-8 min/illumination; and one or two fibers/session. Clinical, laboratory, and US data were obtained immediately before treatment and at 6 and 12 months follow-up and were analyzed by Student's t test and Fisher's exact test. Low- and high-energy subgroups were subsequently defined, and the receiver operating characteristic (ROC) curves were calculated. Results Laser ablation follow-up showed an overall nodule volume reduction of more than 50%; improvement of symptoms and cosmetic complaints (P = 0.001); and stable laboratory data compared with the baseline and control groups. Minor complications were 9.5% (n = 2). One or two fibers/session resulted in a similar nodule volume reduction among 10-18 ml nodules. Analysis of the applied energy suggested a 398.8 J/ml inferior cutoff (ROC curve: 0.889 sensitivity; 0.545 specificity) for the high-energy subgroup (n = 14, mean 599.9 +/- 136.5 J/ml) to reduce the nodule volume over time (-55.1% vs. -58.4%, P = 0.55). The low-energy subgroup (n = 7, mean 240.2 +/- 74.6 J/ml) did not show a persistent volume reduction (P < 0.05) from the 6- to 12-month follow-ups (-56.6% vs. -53.7%). Conclusions Laser ablation of benign TNs achieved technique efficacy at 12 months posttreatment, with clinical improvement and few minor side effects. A single fiber in a single session with a high deployed energy (>398.8 J/ml) may be associated with improved results, a finding to be confirmed with a larger series. Lasers Surg. Med. (c) 2019 Wiley Periodicals, Inc.

Description

Keywords

thyroid nodule, ultrasonography, interventional, laser therapy, ablation techniques, hyperthermia, induced

Language

English

Citation

Lasers In Surgery And Medicine. Hoboken: Wiley, 10 p., 2019.

Related itens

Sponsors

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Units

Departments

Undergraduate courses

Graduate programs

Other forms of access