Logotipo do repositório
 

Publicação:
Biomechanical behavior of endodontically treated premolars using different preparation designs and CAD/CAM materials

Carregando...
Imagem de Miniatura

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Tipo

Artigo

Direito de acesso

Acesso abertoAcesso Aberto

Resumo

Objectives To evaluate the effect of restoration design (‘2.5-mm deep endocrown’, ‘5-mm deep endocrown’ or ‘5-mm deep post&crown’) and CAD/CAM material type (composite or lithium disilicate glass-ceramic) on the load-to-failure of endodontically treated premolars in absence of any ferrule. Methods The crowns of 48 single-rooted premolars were cut and the roots were endodontically treated. Teeth were randomly divided into six groups (n = 8); teeth in each group were restored using one of the two tested materials with standardized CAD/CAM fabricated endocrowns (with either 2.5-mm or 5-mm deep intra-radicular extension) or conventional crowns (5-mm deep post&crown). After cementation using luting composite, the specimens were immersed in distilled water and subjected to 1,200,000 chewing cycles with a load of 50 N applied parallel to the long axis of the tooth (0°). After cyclic loading, a compressive load was applied at 45° to the tooth's long axis using a universal testing machine until failure. Load-to-failure was recorded (N) and the specimens were examined under a stereomicroscope with 3.5x magnification to determine the mode of failure. Results All specimens survived the 1,200,000 chewing cycles. A significant interaction between restoration design and CAD/CAM material was found using two-way ANOVA. In the ‘2.5-mm deep endocrown’ groups, the composite achieved a significantly higher load-to-failure than the lithium disilicate glass-ceramic, while no differences between materials were found in the ‘5-mm deep endocrown’ and ‘5-mm deep post&crown’ groups. More unfavorable failures (root fractures) were observed for higher load-to-failure values. Conclusions Only following a ‘2.5-mm deep endocrown’ design, composite appeared more favorable than lithium disilicate glass-ceramic as crown material; this may be explained by their difference in elastic modulus. Clinical significance Shallow endocrown preparations on premolars present less surface for adhesive luting and a difference in crown material becomes apparent in terms of load-to-failure. The use of a more flexible composite crown material appeared then a better option.

Descrição

Palavras-chave

CAD/CAM, Composite, Compressive load, Cyclic aging, Endocrown, Lithium disilicate

Idioma

Inglês

Como citar

Journal of Dentistry, v. 59, p. 54-61.

Itens relacionados

Financiadores

Coleções

Unidades

Departamentos

Cursos de graduação

Programas de pós-graduação