Logotipo do repositório
 

Publicação:
Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation

dc.contributor.authorMachado, Ana Lucia [UNESP]
dc.contributor.authorGiampaolo, Eunice Teresinha [UNESP]
dc.contributor.authorPavarina, Ana Claudia [UNESP]
dc.contributor.authorJorge, Janaina Habib [UNESP]
dc.contributor.authorVergani, Carlos Eduardo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual de Ponta Grossa (UEPG)
dc.date.accessioned2014-05-20T13:46:36Z
dc.date.available2014-05-20T13:46:36Z
dc.date.issued2012-06-01
dc.description.abstractBackground: This study evaluated the effect of disinfection by immersion and microwave irradiation on the roughness of one denture base resin (Lucitone-L) and five relining materials, three hard (Tokuyama Rebase II-TR, New Truliner-NT, Ufigel Hard-UH) and two resilient (Trusoft-T, Sofreliner-S).Methods: Fifty specimens were made and divided into groups: CL2 specimens were brushed with 4% chlorhexidine (1 min), immersed in the same solution (10 min) and immersed in water (3 min); MW2 specimens were immersed in water and microwave irradiated (650W; 6 min); CL2 and MW2 specimens were disinfected twice; CL7 and MW7 specimens were submitted to seven cycles using chlorhexidine or microwave irradiation, respectively; W specimens were not disinfected and remained in water (37 degrees C; 7 days).Results: Results were statistically analysed (p = 0.05) and revealed that, at baseline, the highest mean value was observed for T (p < 0.001). Material NT showed increase in roughness after the first (p = 0.003), second (p = 0.001), seventh (p = 0.000) cycles of microwave disinfection and after 7 days of immersion in water (p = 0.033).Conclusions: Resilient liner S presented significant increase in roughness after the second cycle of disinfection with chlorhexidine (p = 0.003). Material T exhibited significantly decreased roughness in group W (p = 0.010), while microwaving produced severe alterations on its surface.en
dc.description.affiliationUniv Estadual Paulista UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil
dc.description.affiliationUniversidade Estadual de Ponta Grossa (UEPG), Dept Dent, Maringa, Parana, Brazil
dc.description.affiliationUnespUniv Estadual Paulista UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil
dc.format.extentE375-E382
dc.identifierhttp://dx.doi.org/10.1111/j.1741-2358.2011.00484.x
dc.identifier.citationGerodontology. Hoboken: Wiley-blackwell, v. 29, n. 2, p. E375-E382, 2012.
dc.identifier.doi10.1111/j.1741-2358.2011.00484.x
dc.identifier.issn0734-0664
dc.identifier.lattes8000248781842587
dc.identifier.lattes5737127334248549
dc.identifier.lattes8867670539105403
dc.identifier.lattes3003130522427820
dc.identifier.orcid0000-0002-7375-4714
dc.identifier.urihttp://hdl.handle.net/11449/16506
dc.identifier.wosWOS:000308547000055
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofGerodontology
dc.relation.ispartofjcr1.439
dc.relation.ispartofsjr0,627
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectchemical compoundsen
dc.subjectdenture basesen
dc.subjectdenture rebasingen
dc.subjectmicrowavesen
dc.subjectsurface propertiesen
dc.titleSurface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiationen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
unesp.author.lattes8000248781842587[1]
unesp.author.lattes5737127334248549
unesp.author.lattes8867670539105403[3]
unesp.author.lattes3003130522427820[5]
unesp.author.orcid0000-0002-7375-4714[5]
unesp.author.orcid0000-0002-9135-3455[4]
unesp.author.orcid0000-0002-9231-1994[3]
unesp.author.orcid0000-0002-2718-428X[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: