Atomic pair distribution function at the Brazilian Synchrotron Light Laboratory: Application to the Pb1-xLaxZr0.40Ti0.60O3 ferroelectric system
| dc.contributor.author | Saleta, M. E. | |
| dc.contributor.author | Eleotério, M. | |
| dc.contributor.author | Mesquita, A. [UNESP] | |
| dc.contributor.author | Mastelaro, V. R. | |
| dc.contributor.author | Granado, E. | |
| dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
| dc.contributor.institution | Laboratório Nacional de Luz Síncrotron | |
| dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
| dc.contributor.institution | Universidade de São Paulo (USP) | |
| dc.contributor.institution | CNEA | |
| dc.date.accessioned | 2018-12-11T16:49:14Z | |
| dc.date.available | 2018-12-11T16:49:14Z | |
| dc.date.issued | 2017-09-01 | |
| dc.description.abstract | This work reports the setting up of the X-ray diffraction and spectroscopy beamline at the Brazilian Synchrotron Light Laboratory for performing total scattering experiments to be analyzed by atomic pair distribution function (PDF) studies. The results of a PDF refinement for Al2O3 standard are presented and compared with data acquired at a beamline of the Advanced Photon Source, where it is common to perform this type of experiment. A preliminary characterization of the Pb1-xLaxZr0.40Ti0.60O3 ferroelectric system, with x = 0.11, 0.12 and 0.15, is also shown.A setup for total scattering experiments at the multi-purpose XDS beamline of the Brazilian Synchrotron Light Laboratory (LNLS) is described. Also, a preliminary characterization of the Pb1-xLaxZr0.40Ti0.60O3 (x = 0.11, 0.12 and 0.15) ferroelectric system using pair distribution function analysis is presented. | en |
| dc.description.affiliation | Instituto de Física 'Gleb Wataghin' Universidade de Campinas (UNICAMP) | |
| dc.description.affiliation | Laboratório Nacional de Luz Síncrotron, Caixa Postal 6192 | |
| dc.description.affiliation | Instituto Geociências and Ciências Exatas Universidade Estadual Paulista (UNESP) | |
| dc.description.affiliation | Instituto de Física de São Carlos Universidade de São Paulo, CP 369 | |
| dc.description.affiliation | CONICET - Centro Atómico Bariloche CNEA | |
| dc.description.affiliationUnesp | Instituto Geociências and Ciências Exatas Universidade Estadual Paulista (UNESP) | |
| dc.format.extent | 1098-1104 | |
| dc.identifier | http://dx.doi.org/10.1107/S1600577517008633 | |
| dc.identifier.citation | Journal of Synchrotron Radiation, v. 24, n. 5, p. 1098-1104, 2017. | |
| dc.identifier.doi | 10.1107/S1600577517008633 | |
| dc.identifier.file | 2-s2.0-85028710538.pdf | |
| dc.identifier.issn | 1600-5775 | |
| dc.identifier.issn | 0909-0495 | |
| dc.identifier.scopus | 2-s2.0-85028710538 | |
| dc.identifier.uri | http://hdl.handle.net/11449/170095 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Journal of Synchrotron Radiation | |
| dc.relation.ispartofsjr | 1,650 | |
| dc.relation.ispartofsjr | 1,650 | |
| dc.rights.accessRights | Acesso aberto | pt |
| dc.source | Scopus | |
| dc.subject | atomic pair distribution function | |
| dc.subject | ferroelectric relaxor | |
| dc.subject | X-ray total scattering | |
| dc.title | Atomic pair distribution function at the Brazilian Synchrotron Light Laboratory: Application to the Pb1-xLaxZr0.40Ti0.60O3 ferroelectric system | en |
| dc.type | Artigo | pt |
| dspace.entity.type | Publication | |
| unesp.author.lattes | 2835864951583089[3] | |
| unesp.author.orcid | 0000-0001-8524-0959[3] | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Geociências e Ciências Exatas, Rio Claro | pt |
Arquivos
Pacote original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-85028710538.pdf
- Tamanho:
- 1.43 MB
- Formato:
- Adobe Portable Document Format
- Descrição: