Logotipo do repositório
 

Publicação:
Use of the vertical electrical survey integrated to the chemical and microbiological analyzes in the preliminary diagnosis of soil and groundwater contamination in the rio claro city (SP) municipal cemetery

dc.contributor.authorXavier, Fernanda Vieira [UNESP]
dc.contributor.authorFilho, Walter Malagutti [UNESP]
dc.contributor.authorSilva, Robson Willians da Costa
dc.contributor.authorMoreira, César Augusto [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2018-12-11T17:37:05Z
dc.date.available2018-12-11T17:37:05Z
dc.date.issued2018-03-01
dc.description.abstractPutrefative liquid is an effluent generated from the decomposition of bodies. In cemeteries, the leading cause of subsurface pollution is the liquefaction products percolation, which substantially alter the physical-chemical and biological characteristics of the soil. In Brazil, due to the lack of consistent planning due to cultural history, cemeteries are fully integrated into urban areas, which can be a public health problem. The risk of contamination is associated with the presence of elements such as nitrogen compounds, heavy metals, viruses and bacteria, with risks to human health. In the literature, these contaminants have been consistently identified in the geological environment through analytical results of water and soil compared to non affected areas. This research aimed to investigate possible changes in the subsurface physical environment of the Rio Claro city (São Paulo, Brazil) municipal cemetery, through the analytical results of the wells, supported by data obtained from the geophysical technique of vertical electrical sounding (VES). The results showed good correlation with the spatial and temporal evolution of the occupation of the cemetery throughout its history.en
dc.description.affiliationUniversidade Estadual Paulista “Júlio de Mesquita Filho” (UNESP)
dc.description.affiliationUNESP
dc.description.affiliationUniversidade de São Paulo (USP)
dc.description.affiliationUnespUniversidade Estadual Paulista “Júlio de Mesquita Filho” (UNESP)
dc.description.affiliationUnespUNESP
dc.format.extent333-344
dc.identifierhttp://dx.doi.org/10.1590/S1413-41522018152375
dc.identifier.citationEngenharia Sanitaria e Ambiental, v. 23, n. 2, p. 333-344, 2018.
dc.identifier.doi10.1590/S1413-41522018152375
dc.identifier.fileS1413-41522018000200333.pdf
dc.identifier.issn1413-4152
dc.identifier.lattes9086857312391080
dc.identifier.orcid0000-0002-6949-6679
dc.identifier.scieloS1413-41522018000200333
dc.identifier.scopus2-s2.0-85047068963
dc.identifier.urihttp://hdl.handle.net/11449/179866
dc.language.isopor
dc.relation.ispartofEngenharia Sanitaria e Ambiental
dc.relation.ispartofsjr0,218
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectContaminants
dc.subjectElectrical resistivity
dc.subjectPutrefative liquid
dc.titleUse of the vertical electrical survey integrated to the chemical and microbiological analyzes in the preliminary diagnosis of soil and groundwater contamination in the rio claro city (SP) municipal cemeteryen
dc.titleEmprego da sondagem elétrica vertical integrada às análises químicas e microbiológicas no diagnóstico preliminar da contaminação do solo e da água subterrânea no cemitério municipal da cidade de rio claro (SP)pt
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes9086857312391080[4]
unesp.author.orcid0000-0002-6949-6679[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Geociências e Ciências Exatas, Rio Claropt
unesp.departmentGeologia Aplicada - IGCEpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1413-41522018000200333.pdf
Tamanho:
3.22 MB
Formato:
Adobe Portable Document Format