Publicação:
Laser ablation in titanium implants followed by biomimetic hydroxyapatite coating: Histomorphometric study in rabbits

dc.contributor.authorFaeda, Rafael Silveira
dc.contributor.authorSpin-Neto, Rubens [UNESP]
dc.contributor.authorMarcantonio, Elcio
dc.contributor.authorGuastaldi, Antonio Carlos [UNESP]
dc.contributor.authorMarcantonio, Elcio [UNESP]
dc.contributor.institutionAraraquara Univ
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:31:47Z
dc.date.accessioned2014-05-20T13:45:23Z
dc.date.available2013-09-30T18:31:47Z
dc.date.available2014-05-20T13:45:23Z
dc.date.issued2012-07-01
dc.description.abstractTitanium surface texture and chemistry modification successfully improves the host response and consequently the bone-to-implant contact surrounding dental implants. The aim of the present study was to investigate, using histomorphometrical-analysis, the effects of titanium surface modification by laser-ablation (Nd:YAG) followed by thin chemical deposition of HA. Forty-eight rabbits received one implant by tibiae of AS-machined (MS), laser-modified (LMS), or biomimetic hydroxyapatite-coated (HA) surface. Bone-to-implant contact (BIC) and bone area (BBT) were evaluated after 4, 8, and 12 weeks, at cortical and cancellous regions. Average BIC in the cortical region was higher (P < 0.001) on the LMS and HA implants for all periods, with no differences between LMS and HA. For the cancellous area, the LMS and HA implants showed higher (P < 0.01) BIC than MS at the initial periods. The LMS and HA showed similar values in the cortical region, but a tendency of higher values for HA in the cancellous region was observed in all periods. For the BBT, the differences were found only between HA and MS after 4 weeks in the cortical region (P < 0.05), and after 12 weeks in the cancellous area (P < 0.05). Our results showed that HA biomimetic coating preceded by laser treatment induced the contact osteogenesis and allowed the formation of a more stable boneimplant interface, even in earlier periods. Microsc. Res. Tech., 2012. (C) 2012 Wiley Periodicals, Inc.en
dc.description.affiliationAraraquara Univ, UNIARA, Dept Postgrad Implantol, São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, UNESP, Araraquara Dent Sch, Dept Periodontol, São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, UNESP, Chem Inst Araraquara, Dept Biomat, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Araraquara Dent Sch, Dept Periodontol, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Chem Inst Araraquara, Dept Biomat, São Paulo, Brazil
dc.format.extent940-948
dc.identifierhttp://dx.doi.org/10.1002/jemt.22018
dc.identifier.citationMicroscopy Research and Technique. Hoboken: Wiley-blackwell, v. 75, n. 7, p. 940-948, 2012.
dc.identifier.doi10.1002/jemt.22018
dc.identifier.issn1059-910X
dc.identifier.urihttp://hdl.handle.net/11449/15958
dc.identifier.wosWOS:000305452800015
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofMicroscopy Research and Technique
dc.relation.ispartofjcr1.087
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjecttitanium implantsen
dc.subjectsurface modificationen
dc.subjecthydroxyapatiteen
dc.subjectlaseren
dc.titleLaser ablation in titanium implants followed by biomimetic hydroxyapatite coating: Histomorphometric study in rabbitsen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
unesp.author.lattes6443430122330366[4]
unesp.author.orcid0000-0003-1294-2305[3]
unesp.author.orcid0000-0002-9660-4524[5]
unesp.author.orcid0000-0002-6433-3555[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: