Logotipo do repositório
 

Publicação:
Endodontic retreatment: clinical comparison of reciprocating systems versus rotary system in disinfecting root canals

dc.contributor.authorMartinho, Frederico C. [UNESP]
dc.contributor.authorFreitas, Lilian F.
dc.contributor.authorNascimento, Gustavo G.
dc.contributor.authorFernandes, Aleteia M. [UNESP]
dc.contributor.authorLeite, Fabio R. M.
dc.contributor.authorGomes, Ana P. M. [UNESP]
dc.contributor.authorCamoes, Izabel C. G.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade Federal Fluminense (UFF)
dc.contributor.institutionUniversidade Federal de Pelotas (UFPL)
dc.date.accessioned2015-10-21T13:15:38Z
dc.date.available2015-10-21T13:15:38Z
dc.date.issued2015-07-01
dc.description.abstractIntroduction This clinical study was conducted to compare the effectiveness of single-file reciprocating systems and rotary systems in removing endotoxins and cultivable bacteria in endodontic retreatment.Methods Thirty endodontically treated teeth with post-treatment apical periodontitis were selected. The specimens were divided into three groups according to the system used: WaveOne (n=10), Reciproc instrument (n=10), and ProTaper Universal Retreatment system (n=10). Samples were collected before and after chemomechanical preparation. The irrigation was performed by using 2.5% sodium hypochlorite. A chromogenic limulus amebocyte lysate assay test was used to quantify endotoxins. Culture techniques were used to determine bacterial colony-forming unit counts.Results At baseline, endotoxins and cultivable bacteria were recovered from 100% of the root canal samples in a median value of 5.84 EU/mL and 4.98x10(3) CFU/mL, respectively. After CMP, no differences were found in the median percentage values of endotoxin reduction achieved with reciprocating systems-WaveOne [94.11%] and Reciproc [93.29%] and with rotary systems-ProTaper [94.98%] (P>0.05). Both single-file reciprocating systems [WaveOne (98.27%) and Reciproc (99.54%)] and rotary system [ProTaper (98.73%)] were effective in reducing bacterial load (P>0.05). Moreover, no differences were found among the systems tested.Conclusions The Reciproc and WaveOne reciprocating systems were as effective as the ProTaper system for removal of endotoxins and bacteria in endodontic retreatment.Clinical relevance All systems tested were effective to remove cultivable bacteria and endotoxin in endodontic retreatment. As no differences among systems were observed, it is possible to suggest that clinicians should choose the preferred technique to perform endodontic.en
dc.description.affiliationState Univ Campinas UNICAMP, Piracicaba Dent Sch, Dept Restorat Dent, Endodont Div, Sao Paulo, Brazil
dc.description.affiliationUniv Fed Fluminense, Dept Restorat Dent, Endodont Div, Niteroi, RJ, Brazil
dc.description.affiliationUniv Fed Pelotas, Sch Dent, Dept Semiol &Clin, Periodont Div, Pelotas, RS, Brazil
dc.description.affiliationState Univ Sao Paulo UNESP, Sao Jose dos Campos Dent Sch, Dept Restorat Dent, Endodont Div, BR-12245000 Sao Paulo, Brazil
dc.description.affiliationUnespUniversidade Estadual Paulista, Sao Jose dos Campos Dent Sch, Dept Restorat Dent, Endodont Div, Sao Paulo, Brazil
dc.description.affiliationUnespState Univ Sao Paulo UNESP, Sao Jose dos Campos Dent Sch, Dept Restorat Dent, Endodont Div, BR-12245000 Sao Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.format.extent1411-1417
dc.identifierhttp://link.springer.com/article/10.1007%2Fs00784-014-1360-9
dc.identifier.citationClinical Oral Investigations. Heidelberg: Springer Heidelberg, v. 19, n. 6, p. 1411-1417, 2015.
dc.identifier.doi10.1007/s00784-014-1360-9
dc.identifier.issn1432-6981
dc.identifier.urihttp://hdl.handle.net/11449/128920
dc.identifier.wosWOS:000356774100027
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofClinical Oral Investigations
dc.relation.ispartofjcr2.386
dc.relation.ispartofsjr0,986
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectEndotoxinen
dc.subjectReciprocating motionen
dc.subjectNickel-titanium filesen
dc.subjectEndodontic retreatmenten
dc.titleEndodontic retreatment: clinical comparison of reciprocating systems versus rotary system in disinfecting root canalsen
dc.typeArtigo
dcterms.licensehttp://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0
dcterms.rightsHolderSpringer
dspace.entity.typePublication
unesp.author.lattes7206702993719044[6]
unesp.author.orcid0000-0001-9984-290X[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentOdontologia Restauradora - ICTpt

Arquivos