Publicação:
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles

dc.contributor.authorQuini, Caio C. [UNESP]
dc.contributor.authorMatos, Juliana F. [UNESP]
dc.contributor.authorPróspero, André G. [UNESP]
dc.contributor.authorCalabresi, Marcos Felipe F. [UNESP]
dc.contributor.authorZufelato, Nicholas
dc.contributor.authorBakuzis, Andris F.
dc.contributor.authorBaffa, Oswaldo
dc.contributor.authorMiranda, José Ricardo A. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUFG
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2018-12-11T16:48:52Z
dc.date.available2018-12-11T16:48:52Z
dc.date.issued2015-01-01
dc.description.abstractAlternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200 μL of magnetic nanoparticles with a concentration of 23 mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3 s and 20.6±7.1 s.en
dc.description.affiliationDepartamento de Física e Biofísica Instituto de Biociências UNESP
dc.description.affiliationInstituto de Física UFG
dc.description.affiliationDepartamento de Física FFCLRP USP
dc.description.affiliationUnespDepartamento de Física e Biofísica Instituto de Biociências UNESP
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 2010/07639-9
dc.description.sponsorshipIdFAPESP: 2011/18696-6
dc.format.extent2-6
dc.identifierhttp://dx.doi.org/10.1016/j.jmmm.2014.09.073
dc.identifier.citationJournal of Magnetism and Magnetic Materials, v. 380, p. 2-6.
dc.identifier.doi10.1016/j.jmmm.2014.09.073
dc.identifier.file2-s2.0-85027917197.pdf
dc.identifier.issn0304-8853
dc.identifier.scopus2-s2.0-85027917197
dc.identifier.urihttp://hdl.handle.net/11449/170046
dc.language.isoeng
dc.relation.ispartofJournal of Magnetism and Magnetic Materials
dc.relation.ispartofsjr0,786
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.titleRenal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticlesen
dc.typeArtigo
dspace.entity.typePublication

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...