Logotipo do repositório
 

Publicação:
Development of a pressure nociceptive threshold testing device for evaluation of analgesics in cats

dc.contributor.authorDixon, M. J.
dc.contributor.authorTaylor, P. M.
dc.contributor.authorSteagall, P. V. M.
dc.contributor.authorBrondani, J. T.
dc.contributor.authorLuna, Stélio Pacca Loureiro [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:24:35Z
dc.date.available2014-05-20T15:24:35Z
dc.date.issued2007-02-01
dc.description.abstractA pressure analgesiometric device was developed for unrestrained cats. Eleven cats were studied. Stimulation was via three rounded pins within a bracelet on the forearm. The pins were advanced by manual bladder inflation. Bladder pressure was measured using a strain gauge pressure transducer. The threshold was recorded at the behavioural end point. Thresholds were measured at 5 and 15 min intervals for 2-4 h, after removal/replacement of the cuff, for 120 min after SC butorphanol (0.4 mg/kg), and with mild skin inflammation at the testing site. Data were analysed using ANOVA. Pressure thresholds in untreated cats were around 150 mmHg. The minimum interval for testing was established as 15 min. Data were reproducible over 4 h and beyond 24 h. Thresholds in 5 cats increased (P < 0.05) above baseline for 45 min after butorphanol with a maximum increase of 270 +/- 182 mmHg at 10 min. Thresholds decreased with inflammation. The method appears suitable for feline analgesia investigations. (c) 2006 Elsevier Ltd. All rights reserved.en
dc.description.affiliationUniv Estadual Paulista Julio Mesquita Filho, FMVZ, Fac Vet Med & Anim Sci, Botucatu, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista Julio Mesquita Filho, FMVZ, Fac Vet Med & Anim Sci, Botucatu, SP, Brazil
dc.format.extent85-92
dc.identifierhttp://dx.doi.org/10.1016/j.rvsc.2006.03.010
dc.identifier.citationResearch In Veterinary Science. London: W B Saunders Co Ltd, v. 82, n. 1, p. 85-92, 2007.
dc.identifier.doi10.1016/j.rvsc.2006.03.010
dc.identifier.issn0034-5288
dc.identifier.lattes4473260410099623
dc.identifier.orcid0000-0001-5312-9076
dc.identifier.urihttp://hdl.handle.net/11449/35166
dc.identifier.wosWOS:000243626500016
dc.language.isoeng
dc.publisherW B Saunders Co Ltd
dc.relation.ispartofResearch in Veterinary Science
dc.relation.ispartofjcr1.616
dc.relation.ispartofsjr0,593
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectpressure thresholdpt
dc.subjectcatpt
dc.subjectanalgesiapt
dc.subjectpainpt
dc.subjectequipmentpt
dc.subjectmeasurementpt
dc.subjectpressure nociceptive threshold testingpt
dc.subjectopioidpt
dc.subjectNSAIDpt
dc.titleDevelopment of a pressure nociceptive threshold testing device for evaluation of analgesics in catsen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderW B Saunders Co Ltd
dspace.entity.typePublication
unesp.author.lattes4473260410099623
unesp.author.orcid0000-0001-5312-9076[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária e Zootecnia, Botucatupt
unesp.departmentCirurgia e Anestesiologia Veterinária - FMVZpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: