Logotipo do repositório
 

Publicação:
Influence of sealing of the screw access hole on the fracture resistance of implant-supported restorations

dc.contributor.authorPereira, Rodrigo de Paula [UNESP]
dc.contributor.authorRocha, Cibele Oliveira de Melo [UNESP]
dc.contributor.authorReis, José Maurício dos Santos Nunes [UNESP]
dc.contributor.authorArioli-Filho, João Neudenir [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:02:13Z
dc.date.available2018-12-11T17:02:13Z
dc.date.issued2016-03-01
dc.description.abstractThe purpose of this study was to assess the influence of sealing of the screw access hole (SAH) on the fracture resistance of metal-ceramic implant-supported restorations. UCLA abutments were used to make 30 implant-retained mandibular molar restorations and divide equally into three groups: Group SRS: screw-retained restorations with SAH sealed; Group SRNS: screw-retained restorations with SAH not sealed; Group CR: cement-retained restorations. The following protocol was adopted to restore the SAH: the ceramic surface of the SAH was air-abraded with aluminum oxide; etched with 10% hydrofluoric acid; a silane coupling agent and a bonding agent were applied; cotton pellets were used as filling material and P-60 resin composite as restoring material. The cement-retained restorations were cemented with Rely-X U100. A metal rod with a spherical tip of 6.0 mm diameter was used to apply a vertical static load, simultaneously on the buccal and lingual incline cusps, at a crosshead speed of 0.5 mm/min until the fracture of the specimens. Data were analyzed using one-way ANOVA and Dunnet test (p<0.05) for multiples comparisons. The mode of failure was evaluated by a scanning electron microscopy (SEM). No significant difference between screw-retained restorations was found. The highest mean fracture resistance values were observed with CR group. Therefore, it was shown that SAH sealing did not influence the fracture resistance of the screw-retained restorationsen
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araraquara Dental School UNESP-Universidade Estadual Paulista
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araraquara Dental School UNESP-Universidade Estadual Paulista
dc.format.extent148-152
dc.identifierhttp://dx.doi.org/10.1590/0103-6440201600575
dc.identifier.citationBrazilian Dental Journal, v. 27, n. 2, p. 148-152, 2016.
dc.identifier.doi10.1590/0103-6440201600575
dc.identifier.fileS0103-64402016000200148.pdf
dc.identifier.issn1806-4760
dc.identifier.issn0103-6440
dc.identifier.scieloS0103-64402016000200148
dc.identifier.scopus2-s2.0-84962779401
dc.identifier.urihttp://hdl.handle.net/11449/172800
dc.language.isoeng
dc.relation.ispartofBrazilian Dental Journal
dc.relation.ispartofsjr0,476
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectCement-retained implant-supported restoration
dc.subjectFracture resistance
dc.subjectScrew access hole
dc.subjectScrew-retained implant-supported restoration
dc.titleInfluence of sealing of the screw access hole on the fracture resistance of implant-supported restorationsen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0103-64402016000200148.pdf
Tamanho:
1.36 MB
Formato:
Adobe Portable Document Format