Logotipo do repositório
 

Publicação:
Degree of conversion of different composite resins photo-activated with light-emitting diode and argon ion laser

dc.contributor.authorMessias, A M [UNESP]
dc.contributor.authorGalvão, M R [UNESP]
dc.contributor.authorBoaventura, J M C [UNESP]
dc.contributor.authorJacomassi, D P
dc.contributor.authorBernardi, M I B
dc.contributor.authorBagnato, V S
dc.contributor.authorRastelli, Alessandra Nara de Souza [UNESP]
dc.contributor.authorAndrade, Marcelo Ferrarezi [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2015-08-06T16:13:58Z
dc.date.available2015-08-06T16:13:58Z
dc.date.issued2015
dc.description.abstractThis study evaluated the degree of conversion (DC%) of one experimental and different brands of composite resins light-cured by two light sources (one LED and one argon laser). The percentage of unreacted C = C was determined from the ratio of absorbance intensities of aliphatic C = C (peak at 1637 cm−1) against internal standards before and after curing: aromatic C–C (peak at 1610 cm−1) except for P90, where %C = C bonds was given for C–O–C (883 cm−1) and C–C (1257 cm−1). ANOVA and Tukey's test revealed no statistically significant difference among Z350 (67.17), Z250 (69.52) and experimental (66.61  ±  2.03) with LED, just among them and Evolu-X (75.51) and P90 (32.05) that showed higher and lower DC%, respectively. For the argon laser, there were no differences among Z250 (70.67), Z350 (69.60), experimental (65.66) and Evolu-X (73, 37), however a significant difference was observed for P90 (36.80), which showed lowest DC%. The light sources showed similar DC%, however the main difference was observed regarding the composite resins. The lowest DC% was observed for the argon laser. P90 showed the lowest DC% for both light-curing sources.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680 3 andar, sala n 314, Centro, CEP 14801-903, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680 3 andar, sala n 314, Centro, CEP 14801-903, SP, Brasil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipFundação para o Desenvolvimento da Unesp (FUNDUNESP)
dc.description.sponsorshipIdFAPESP: 2010/08998-2
dc.description.sponsorshipIdFUNDUNESP: 00832/11
dc.format.extent25601
dc.identifierhttp://iopscience.iop.org/1555-6611/25/2/025601
dc.identifier.citationLaser Physics, v. 25, n. 2, p. 025601, 2015.
dc.identifier.doi10.1088/1054-660X/25/2/025601
dc.identifier.issn1054-660X
dc.identifier.lattes6914969526213393
dc.identifier.urihttp://hdl.handle.net/11449/126106
dc.language.isoeng
dc.relation.ispartofLaser Physics
dc.relation.ispartofjcr1.158
dc.rights.accessRightsAcesso restritopt
dc.sourceCurrículo Lattes
dc.subjectComposite resinsen
dc.subjectAargon ion laseren
dc.subjectLEDen
dc.subjectPhotopolymerizationen
dc.titleDegree of conversion of different composite resins photo-activated with light-emitting diode and argon ion laserpt
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes6914969526213393[7]
unesp.author.orcid0000-0002-6768-2670[7]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos