Publicação: Stress analysis of axial and tilted implants in full-arch fixed dentures under different abutment conditions
dc.contributor.author | Mazaro, Jose Vitor Quinelli [UNESP] | |
dc.contributor.author | Da Silva, Cristina Ramos [UNESP] | |
dc.contributor.author | Filho, Humberto Gennari [UNESP] | |
dc.contributor.author | Zavanelli, Adriana Cristina [UNESP] | |
dc.contributor.author | De Mello, Caroline Cantieri [UNESP] | |
dc.contributor.author | Lemos, Cleidiel Aparecido Araujo [UNESP] | |
dc.contributor.author | Pellizzer, Eduardo Piza [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2018-12-11T17:01:55Z | |
dc.date.available | 2018-12-11T17:01:55Z | |
dc.date.issued | 2016-01-01 | |
dc.description.abstract | The aim of this study was to evaluate the stress distribution on fullarch prostheses, considering axial implants and tilted implants with or without abutments. Two photoelastic models were made, being that in 1 model the implants were inserted perpendicular, whereas in the other model 2 implants were inserted perpendicular and 2 implants were inserted with tilting 308 to the distal area. The prosthetic situations were evaluated: A-axial implants and nonsegmented full-arch prosthesis; B-axial implants and segmented full-arch prosthesis; C-tilted distal implants and nonsegmented full-arch prosthesis; D-tilted distal implants and segmented fullarch prosthesis, and was applied an axial load of 100N at 5 points. The results showed greater stress concentration for axial implants than tilted implants in anterior and posterior loading. There was no difference in stress distribution to the use of abutment in the tilted implants. Shorter cantilever with tilted implants improved the stress distribution; the use of abutment did not influence the stress distribution. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Araçatuba Dental School UNESP-Univ Estadual Paulista, José Bonifácio St, 1193 | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Araçatuba Dental School UNESP-Univ Estadual Paulista, José Bonifácio St, 1193 | |
dc.format.extent | e249-e252 | |
dc.identifier | http://dx.doi.org/10.1097/SCS.0000000000002455 | |
dc.identifier.citation | Journal of Craniofacial Surgery, v. 27, n. 3, p. e249-e252, 2016. | |
dc.identifier.doi | 10.1097/SCS.0000000000002455 | |
dc.identifier.issn | 1536-3732 | |
dc.identifier.issn | 1049-2275 | |
dc.identifier.lattes | 8942804819076392 | |
dc.identifier.orcid | 0000-0003-1781-1953 | |
dc.identifier.scopus | 2-s2.0-84961393319 | |
dc.identifier.uri | http://hdl.handle.net/11449/172725 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Craniofacial Surgery | |
dc.relation.ispartofsjr | 0,448 | |
dc.relation.ispartofsjr | 0,448 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | Bone resorption | |
dc.subject | Dental implants | |
dc.subject | Dental prosthesis | |
dc.title | Stress analysis of axial and tilted implants in full-arch fixed dentures under different abutment conditions | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 8942804819076392[4] | |
unesp.author.orcid | 0000-0003-1781-1953[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |