Logotipo do repositório
 

Publicação:
Stress analysis of axial and tilted implants in full-arch fixed dentures under different abutment conditions

dc.contributor.authorMazaro, Jose Vitor Quinelli [UNESP]
dc.contributor.authorDa Silva, Cristina Ramos [UNESP]
dc.contributor.authorFilho, Humberto Gennari [UNESP]
dc.contributor.authorZavanelli, Adriana Cristina [UNESP]
dc.contributor.authorDe Mello, Caroline Cantieri [UNESP]
dc.contributor.authorLemos, Cleidiel Aparecido Araujo [UNESP]
dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:01:55Z
dc.date.available2018-12-11T17:01:55Z
dc.date.issued2016-01-01
dc.description.abstractThe aim of this study was to evaluate the stress distribution on fullarch prostheses, considering axial implants and tilted implants with or without abutments. Two photoelastic models were made, being that in 1 model the implants were inserted perpendicular, whereas in the other model 2 implants were inserted perpendicular and 2 implants were inserted with tilting 308 to the distal area. The prosthetic situations were evaluated: A-axial implants and nonsegmented full-arch prosthesis; B-axial implants and segmented full-arch prosthesis; C-tilted distal implants and nonsegmented full-arch prosthesis; D-tilted distal implants and segmented fullarch prosthesis, and was applied an axial load of 100N at 5 points. The results showed greater stress concentration for axial implants than tilted implants in anterior and posterior loading. There was no difference in stress distribution to the use of abutment in the tilted implants. Shorter cantilever with tilted implants improved the stress distribution; the use of abutment did not influence the stress distribution.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araçatuba Dental School UNESP-Univ Estadual Paulista, José Bonifácio St, 1193
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araçatuba Dental School UNESP-Univ Estadual Paulista, José Bonifácio St, 1193
dc.format.extente249-e252
dc.identifierhttp://dx.doi.org/10.1097/SCS.0000000000002455
dc.identifier.citationJournal of Craniofacial Surgery, v. 27, n. 3, p. e249-e252, 2016.
dc.identifier.doi10.1097/SCS.0000000000002455
dc.identifier.issn1536-3732
dc.identifier.issn1049-2275
dc.identifier.lattes8942804819076392
dc.identifier.orcid0000-0003-1781-1953
dc.identifier.scopus2-s2.0-84961393319
dc.identifier.urihttp://hdl.handle.net/11449/172725
dc.language.isoeng
dc.relation.ispartofJournal of Craniofacial Surgery
dc.relation.ispartofsjr0,448
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.subjectBone resorption
dc.subjectDental implants
dc.subjectDental prosthesis
dc.titleStress analysis of axial and tilted implants in full-arch fixed dentures under different abutment conditionsen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes8942804819076392[4]
unesp.author.orcid0000-0003-1781-1953[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt