Publicação: Immunoassay quantification using surface-enhanced fluorescence (SEF) tags
dc.contributor.author | Camacho, S. A. [UNESP] | |
dc.contributor.author | Sobral-Filho, R. G. | |
dc.contributor.author | Aoki, P. H.B. [UNESP] | |
dc.contributor.author | Constantino, C. J.L. [UNESP] | |
dc.contributor.author | Brolo, A. G. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | University of Victoria | |
dc.date.accessioned | 2018-12-11T17:13:34Z | |
dc.date.available | 2018-12-11T17:13:34Z | |
dc.date.issued | 2017-08-07 | |
dc.description.abstract | Fluorescence-based immonoassays are widely used in several areas, ranging from basic biomedical research to disease diagnostics. A variety of new probes have been developed recently to address some limitations in typical assays performed with organic dyes. Ideally, new fluorescence tags that allow quantification with a low limit of detection are highly desired. In this work, the surface-enhanced fluorescence (SEF) phenomenon was explored in the development of tags for Immunoglobulin-M (IgM) detection. Shell-isolated gold nanoparticles (Au-SHINs) with 100 nm core size and a 10 nm silica shell were synthesized. These particles contain an outermost thin fluorescent layer of nile blue (NB) that was further coated by another 5 nm of silica (SEF tags). The outer silica shell was then functionalized with antibodies to allow the detection of IgM as in typical immunological sandwich assays. IgM concentrations down to the 10 ng mL-1 mark were successfully detected. A linear dependence between the average fluorescence intensity and the IgM concentration was found. | en |
dc.description.affiliation | São Paulo State University (UNESP) School of Technology and Applied Sciences Campus Presidente Prudente | |
dc.description.affiliation | University of Victoria Department of Chemistry | |
dc.description.affiliation | São Paulo State University (UNESP) School of Sciences Humanities and Languages Campus Assis | |
dc.description.affiliationUnesp | São Paulo State University (UNESP) School of Technology and Applied Sciences Campus Presidente Prudente | |
dc.description.affiliationUnesp | São Paulo State University (UNESP) School of Sciences Humanities and Languages Campus Assis | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Natural Sciences and Engineering Research Council of Canada | |
dc.description.sponsorship | Työ- ja Elinkeinoministeriö | |
dc.format.extent | 2717-2724 | |
dc.identifier | http://dx.doi.org/10.1039/c7an00639j | |
dc.identifier.citation | Analyst, v. 142, n. 15, p. 2717-2724, 2017. | |
dc.identifier.doi | 10.1039/c7an00639j | |
dc.identifier.issn | 1364-5528 | |
dc.identifier.issn | 0003-2654 | |
dc.identifier.lattes | 7384168674539702 | |
dc.identifier.orcid | 0000-0003-4701-6408 | |
dc.identifier.scopus | 2-s2.0-85025807026 | |
dc.identifier.uri | http://hdl.handle.net/11449/174948 | |
dc.language.iso | eng | |
dc.relation.ispartof | Analyst | |
dc.relation.ispartofsjr | 1,249 | |
dc.relation.ispartofsjr | 1,249 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.title | Immunoassay quantification using surface-enhanced fluorescence (SEF) tags | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.lattes | 7384168674539702[3] | |
unesp.author.lattes | 6118325967319836[4] | |
unesp.author.orcid | 0000-0003-4701-6408[3] | |
unesp.author.orcid | 0000-0002-5921-3161[4] | |
unesp.department | Estatística - FCT | pt |