Logotipo do repositório
 

Publicação:
Instrumentation of dental implants: a literature review

dc.contributor.authorCurylofo, Fabiana de Almeida [UNESP]
dc.contributor.authorBarbosa, Lígia Araújo [UNESP]
dc.contributor.authorRibeiro, Ana Lúcia Roselino [UNESP]
dc.contributor.authorFais, Laiza Maria Grassi [UNESP]
dc.contributor.authorVaz, Luis Geraldo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-08-06T16:13:11Z
dc.date.available2015-08-06T16:13:11Z
dc.date.issued2013
dc.description.abstractThe aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680 - Sala 409 - Quarto Andar, Centro, CEP 14801903, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680 - Sala 409 - Quarto Andar, Centro, CEP 14801903, SP, Brasil
dc.description.affiliationUnespDepartment of Diagnosis and Surgery, School of Dentistry, São Paulo State University – Araraquara – SP – Brazil.
dc.format.extent82-88
dc.identifierhttp://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-56852013000100014&lng=pt&nrm=iso&tlng=en
dc.identifier.citationRSBO. Revista Sul-Brasileira de Odontologia, v. 10, n. 1, p. 82-88, 2013.
dc.identifier.issn1984-5685
dc.identifier.lattes6227346732067001
dc.identifier.lattes8787696766930781
dc.identifier.lattes8547747556446020
dc.identifier.urihttp://hdl.handle.net/11449/125816
dc.language.isoeng
dc.relation.ispartofRSBO. Revista Sul-Brasileira de Odontologia
dc.rights.accessRightsAcesso aberto
dc.sourceCurrículo Lattes
dc.subjectDental implantsen
dc.subjectInstrumentationen
dc.subjectPrevention and controlen
dc.titleInstrumentation of dental implants: a literature reviewen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6227346732067001
unesp.author.lattes8787696766930781
unesp.author.lattes8547747556446020
unesp.author.orcid0000-0003-0916-1962[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos