Publicação: Preliminary tribo-electrochemical and biological responses of the Ti-TiB-TiCx in-situ composites intended for load-bearing biomedical implants
dc.contributor.author | Sousa, L. | |
dc.contributor.author | Alves, A. C. | |
dc.contributor.author | Costa, N. A. [UNESP] | |
dc.contributor.author | Gemini-Piperni, S. | |
dc.contributor.author | Rossi, A. L. | |
dc.contributor.author | Ribeiro, A. R. | |
dc.contributor.author | Simões, S. | |
dc.contributor.author | Toptan, F. | |
dc.contributor.institution | CMEMS-UMinho – Center of MicroElectroMechanical Systems – Universidade do Minho | |
dc.contributor.institution | DEMM – Department of Metallurgical and Materials Engineering – Faculdade de Engenharia da Universidade do Porto | |
dc.contributor.institution | Azurém | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | Tribocorrosion and Nanomedicine | |
dc.contributor.institution | R. Dr. Xavier Sigaud | |
dc.contributor.institution | Universidade do Grande Rio | |
dc.contributor.institution | Institute of Science and Innovation in Mechanical and Industrial Engineering | |
dc.contributor.institution | Izmir Institute of Technology | |
dc.contributor.institution | Universidade Federal do Rio de Janeiro (UFRJ) | |
dc.date.accessioned | 2022-04-28T19:48:11Z | |
dc.date.available | 2022-04-28T19:48:11Z | |
dc.date.issued | 2022-03-10 | |
dc.description.abstract | Poor tribocorrosion resistance of Ti and its alloys remains as a concern for load-bearing biomedical implants. Despite being an effective method to improve tribocorrosion resistance, titanium matrix composites (TMCs) have yet to be used in this type of applications. In-situ TiB (titanium boride) and TiC (titanium carbide) reinforcement phases have been considered as one of the best options to produce TMCs once these phases present high compatibility and strong interfacial bonding with Ti. Although the effect of these phases on the mechanical properties of Ti has been thoroughly researched in the last years, their effect on corrosion, tribocorrosion and biocompatibility of Ti is yet to be fully understood. In this work, in-situ Ti-TiB-TiCx composites obtained by reactive hot pressing showed identical corrosion response compared to the unreinforced Ti but displayed improved tribocorrosion behaviour. Under 0.5 N load, composites presented as average a reduction of 51% in wear volume loss and under 10 N the reduction was up to 93%. Early biological tests showed promising results, as composites were biocompatible and induced osteoblasts spreading and possibly proliferation most probably due to composite chemistry and surface hardness. | en |
dc.description.affiliation | CMEMS-UMinho – Center of MicroElectroMechanical Systems – Universidade do Minho Campus de Azurém | |
dc.description.affiliation | DEMM – Department of Metallurgical and Materials Engineering – Faculdade de Engenharia da Universidade do Porto | |
dc.description.affiliation | IBTN/Euro – European Branch of the Institute of Biomaterials Tribocorrosion and Nanomedicine Dept. Eng. Mecânica Universidade do Minho Azurém | |
dc.description.affiliation | UNESP – Universidade Estadual Paulista Faculdade de Ciências | |
dc.description.affiliation | IBTN/Br – Brazilian Branch of the Institute of Biomaterials Tribocorrosion and Nanomedicine | |
dc.description.affiliation | Centro Brasileiro de Pesquisas Físicas (CBPF) R. Dr. Xavier Sigaud, 150 - Urca | |
dc.description.affiliation | Universidade do Grande Rio, Rua Professor José de Souza Herdy, 1160 | |
dc.description.affiliation | LAETA/INEGI Institute of Science and Innovation in Mechanical and Industrial Engineering, R. Dr. Roberto Frias | |
dc.description.affiliation | Department of Materials Science and Engineering Izmir Institute of Technology | |
dc.description.affiliation | Universidade Federal do Rio de Janeiro (UFRJ) | |
dc.description.affiliationUnesp | UNESP – Universidade Estadual Paulista Faculdade de Ciências | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Nuclear Fuel Cycle and Supply Chain | |
dc.description.sponsorshipId | CAPES: #2017/24319-7 | |
dc.description.sponsorshipId | FAPESP: #2018/25532-9 | |
dc.description.sponsorshipId | FAPESP: 08-5369-FSE-000051 | |
dc.description.sponsorshipId | Nuclear Fuel Cycle and Supply Chain: UID/EEA/04436/2019 | |
dc.identifier | http://dx.doi.org/10.1016/j.jallcom.2021.162965 | |
dc.identifier.citation | Journal of Alloys and Compounds, v. 896. | |
dc.identifier.doi | 10.1016/j.jallcom.2021.162965 | |
dc.identifier.issn | 0925-8388 | |
dc.identifier.scopus | 2-s2.0-85120888579 | |
dc.identifier.uri | http://hdl.handle.net/11449/223014 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Alloys and Compounds | |
dc.source | Scopus | |
dc.subject | Corrosion | |
dc.subject | Load-bearing implants | |
dc.subject | Osteoblasts | |
dc.subject | Titanium matrix composites | |
dc.subject | Tribocorrosion | |
dc.title | Preliminary tribo-electrochemical and biological responses of the Ti-TiB-TiCx in-situ composites intended for load-bearing biomedical implants | en |
dc.type | Artigo | |
dspace.entity.type | Publication |