Logotipo do repositório
 

Publicação:
Comparison of the tensile bond strengths of cast metal crowns luted with resin cements

dc.contributor.authorFonseca, Renata Garcia [UNESP]
dc.contributor.authordos Santos Cruz, C. A.
dc.contributor.authorAdabo, Gelson Luis [UNESP]
dc.contributor.authorVaz, Luis Geraldo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:21:33Z
dc.date.available2014-05-20T15:21:33Z
dc.date.issued2004-11-01
dc.description.abstractThe limitation of photoactivation of dual-polymerized resin cements along the margins of metal restorations may adversely affect the mechanical properties of these cements, thus impairing the retention of restorations. The aim of this study was to assess the bond strength of cast metal crowns cemented with three dual-polymerized resin cements, using a chemically-activated resin cement and zinc phosphate as controls. Fifty nickel-chromium alloy crowns were cast and randomly assigned to five groups of equal size. Castings were cemented on their corresponding metal dies with one of the tested luting agents: Scotchbond Resin Cement, Enforce and Panavia F (dual-polymerized resin cements), Cement-It (chemically-activated resin cement) and Zinc Phosphate Cement (zinc phosphate cement). Specimens were stored in distilled water at 37 degreesC for 24 h and then loaded in tension until failure. Panavia F and Zinc Phosphate Cement provided the highest and lowest bond strength means, respectively. Scotchbond Resin Cement, Enforce and Cement-It cements exhibited similar intermediate values, but with statistically significant difference compared to the other materials (P < 0.05). Even with the restriction or absence of light activation, all tested dual-polymerized resin cements produced significantly higher bond strength than did the zinc phosphate cement and yielded similar or better results than the chemically activated cement. It should be pointed out that the findings of this study relate to a test scenario which does not mimic clinical circumstances and that further work is required to identify the clinical significance of the reported tensile bond strength differences between the different luting materials.en
dc.description.affiliationUNESP, Araraquara Dent Sch, Araraquara, SP, Brazil
dc.description.affiliationUnespUNESP, Araraquara Dent Sch, Araraquara, SP, Brazil
dc.format.extent1080-1084
dc.identifierhttp://dx.doi.org/10.1111/j.1365-2842.2004.01345.x
dc.identifier.citationJournal of Oral Rehabilitation. Oxford: Blackwell Publishing Ltd, v. 31, n. 11, p. 1080-1084, 2004.
dc.identifier.doi10.1111/j.1365-2842.2004.01345.x
dc.identifier.issn0305-182X
dc.identifier.lattes3041561340615890
dc.identifier.lattes9056474544845038
dc.identifier.lattes2851339311179809
dc.identifier.lattes8547747556446020
dc.identifier.urihttp://hdl.handle.net/11449/32679
dc.identifier.wosWOS:000224812400007
dc.language.isoeng
dc.publisherBlackwell Publishing
dc.relation.ispartofJournal of Oral Rehabilitation
dc.relation.ispartofjcr2.051
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectresin cementspt
dc.subjectcast metal crownspt
dc.subjecttensile bond strengthpt
dc.titleComparison of the tensile bond strengths of cast metal crowns luted with resin cementsen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderBlackwell Publishing Ltd
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes3041561340615890
unesp.author.lattes9056474544845038[2]
unesp.author.lattes2851339311179809
unesp.author.lattes8547747556446020
unesp.author.orcid0000-0002-0734-7926[3]
unesp.author.orcid0000-0003-0916-1962[4]
unesp.author.orcid0000-0001-6657-913X[1]
unesp.author.orcid0000-0001-8406-4797[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: