Repository logo
 

Publication:
The effect of implant design on insertion torque and immediate micromotion

dc.contributor.authorFreitas, Amilcar C.
dc.contributor.authorBonfante, Estevam A.
dc.contributor.authorGiro, Gabriela [UNESP]
dc.contributor.authorJanal, Malvin N.
dc.contributor.authorCoelho, Paulo G.
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionNYU
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:31:46Z
dc.date.accessioned2014-05-20T13:45:22Z
dc.date.available2013-09-30T18:31:46Z
dc.date.available2014-05-20T13:45:22Z
dc.date.issued2012-01-01
dc.description.abstractObjectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.en
dc.description.affiliationUniv São Paulo, Bauru Sch Dent, Dept Prosthodont, Bauru, SP, Brazil
dc.description.affiliationNYU, Dept Biomat & Biomimet, New York, NY USA
dc.description.affiliationUniv Estadual Paulista, Fac Odontol Araraquara, Dept Oral Diag & Surg, Araraquara, SP, Brazil
dc.description.affiliationNYU, Coll Dent, Dept Epidemiol & Hlth Promot, New York, NY USA
dc.description.affiliationUnespUniv Estadual Paulista, Fac Odontol Araraquara, Dept Oral Diag & Surg, Araraquara, SP, Brazil
dc.format.extent113-118
dc.identifierhttp://dx.doi.org/10.1111/j.1600-0501.2010.02142.x
dc.identifier.citationClinical Oral Implants Research. Malden: Wiley-blackwell, v. 23, n. 1, p. 113-118, 2012.
dc.identifier.doi10.1111/j.1600-0501.2010.02142.x
dc.identifier.issn0905-7161
dc.identifier.urihttp://hdl.handle.net/11449/15955
dc.identifier.wosWOS:000298548900018
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofClinical Oral Implants Research
dc.relation.ispartofjcr4.305
dc.relation.ispartofsjr2,462
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectdental implanten
dc.subjectinsertion torqueen
dc.subjectmicromotionen
dc.subjectosseointegrationen
dc.subjectprimary stabilityen
dc.titleThe effect of implant design on insertion torque and immediate micromotionen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.orcid0000-0002-7590-8158[3]
unesp.author.orcid0000-0001-6867-8350[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Files

License bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: