dc.description.abstractProblemas associados à manipulação das vias aéreas em pacientes obesos desafiam os anestesiologistas. O objetivo deste estudo foi comparar o uso do Airtraq® com o laringoscópio convencional observando-se o tempo de intubação traqueal, a necessidade de manobras facilitadoras, o grau de visualização das cordas vocais, bem como a influência de variáveis anatômicas na intubação traqueal de pacientes obesos posicionados em rampa. Em cento e trinta e dois pacientes, de ambos os sexos, com índice de massa corporal > 35 kg.m-2 e idade entre 18 e 60 anos, candidatos à cirurgia bariátrica, anotou-se o perímetro cervical, a distância mento-fúrcula e interincisivos, e o índice de Mallampati. Antes da indução da anestesia e após posicionamento com coxins dorsais (ramped position), os pacientes foram aleatoriamente divididos em dois grupos, de acordo com o dispositivo empregado para a intubação traqueal: laringoscópio de Macintosh (n = 64) ou Airtraq® (n = 68). Foram avaliados o índice de Cormack e Lehane, o tempo para intubação, os valores da saturação de pulso de oxigênio (SpO2), a pressão arterial média (PAM) e a frequência cardíaca. Observou-se o número de tentativas e necessidade de auxilio para a intubação. Houve falha na intubação em dois pacientes do grupo laringoscópio de Macintosh, que foram incluídos na análise por intenção de tratamento no pior cenário. O tempo de intubação foi menor com o Airtraq® (13,7 ± 3,1 segundos) do que com o laringoscópio de Macintosh (36,9 ± 22,8 segundos) (P<0,01). Os valores da SpO2 não apresentaram variação com relevância clínica e a PAM foi significativamente mais baixa no grupo Airtraq® três minutos após a intubação traqueal, 82,0 ± 11,4 mmHg e 76,9 ± 12,5 mmHg (P<0,05) nos grupos Airtraq® e laringoscópio de Macintosh, respectivamente...pt
dc.description.abstractAirway management in bariatric surgery is a major challenge for anaesthesiologists. Thus, the aim of this study was to investigate the time required for tracheal intubation, the number of attempts to intubate, larynx visualization and the need for manoeuvres to optimize the glottis view of obese patients in ramped position by comparing the AirtraqTM and Macintosh laryngoscopes. Likewise, the influence of anatomical variables on intubation time was investigated. From 132 bariatric surgery patients with body mass index ≥35 kg.m-2 and aged 18 to 60 years, cervical perimeter, sternomental distance, interincisor distance, and Mallampati score were recorded. Patients were randomised into two groups according to whether a Macintosh (n = 64) or an AirtraqTM (n = 68) laryngoscope was used for tracheal intubation. Cormack & Lehane score, time required for intubation, pulse oximetry (SpO2), mean arterial pressure (MAP), and heart rate were assessed. Characteristics and consequences of airway management were evaluated. Intubation failed in two patients in the Macintosh laryngoscope group, and these patients were considered as worst case scenario (intention to treat analysis). The intubation times were 13.7 ± 3.1 seconds and 36.9 ± 22.8 seconds for AirtraqTM and Macintosh laryngoscope groups (P<0.01), respectively. The SpO2 values did not exhibit clinically relevant variation, and MAP was significantly lower in the AirtraqTM group three minutes after tracheal intubation. Cormack-Lehane scores were also lower for the AirtraqTM group. One patient in the Macintosh group with intubation failure was quickly intubated with the AirtraqTM. Cervical circumference (P<0.01) and interincisor distance (P<0.05) influenced the time required for intubation in the Macintosh group but not in the AirtraqTM group. For obese patients in the ramped... (Complete abstract click electronic access below)en
dc.format.extent71 f.
dc.identifier.aleph000713568
dc.identifier.capes33004064076P6
dc.identifier.citationRANIERI JUNIOR, Dante. Uso do Airtraq® em cirurgias bariátricas: influência do posicionamento. 2012. 71 f. Tese (doutorado) - Universidade Estadual Paulista Julio de Mesquita Filho, Faculdade de Medicina de Botucatu, 2012.
dc.identifier.fileranierijunior_d_dr_botfm.pdf
dc.identifier.lattes8745358989680600
dc.identifier.orcid0000-0002-2323-9159
dc.identifier.urihttp://hdl.handle.net/11449/105632
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.sourceAleph
dc.subjectCirurgia bariátricapt
dc.subjectLaringoscopiapt
dc.subjectObesidade - Tratamentopt
dc.subjectLaringe - Intubaçãopt
dc.subjectTraqueia - Intubaçãopt
dc.subjectObesity - Surgerypt
dc.titleUso do Airtraq® em cirurgias bariátricas: influência do posicionamentopt
dc.typeTese de doutorado
dspace.entity.typePublication
unesp.advisor.lattes8745358989680600
unesp.advisor.orcid0000-0002-2323-9159
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.graduateProgramAnestesiologia - FMBpt
unesp.knowledgeAreaQualidade e segurança em anestesiologiapt
unesp.researchAreaAnestesiologiapt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
ranierijunior_d_dr_botfm.pdf
Tamanho:
713.16 KB
Formato:
Adobe Portable Document Format