Logotipo do repositório
 

Publicação:
Comparative study between two techniques of incisional hernia repair with polypropylene mesh in rabbits

dc.contributor.authorMinossi, José Guilherme [UNESP]
dc.contributor.authorCaramori, Carlos Antonio [UNESP]
dc.contributor.authorLeite, Celso Vieira de Souza [UNESP]
dc.contributor.authorNaresse, Luiz Eduardo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:33:39Z
dc.date.available2014-05-20T13:33:39Z
dc.date.issued2010-10-01
dc.description.abstractOBJETIVO: Comparar duas técnicas de tratamento da hérnia incisional em coelhos utilizando a tela de polipropileno apoiando um reforço peritônio - aponeurótico ou suturada nas bordas do anel herniário 'em ponte . MÉTODOS: Foram operados 60 coelhos para a produção de hérnia incisional, em uma incisão mediana de 4 centímetros. Após 30 dias, metade dos animais foram operados com o fechamento primário da parede, com colocação de uma tela de polipropileno apoiando o reforço e a outra metade dos animais com a colocação da tela suturada nas bordas do anel herniárioem ponte . Os animais foram avaliados com 30 (M1), 60 (M2)e 90 (M3) dias de pós-operatório. Os parâmetros analisados foram a evolução clínica, análise da força de ruptura da cicatriz, estudo macroscópico, análise microscópica e morfométrica. RESULTADOS: Não foram observadas diferenças significantes com relação a força de ruptura e estudos histológicos nos dois grupos e vários momentos estudados. Não houve diferença estatística com relação às complicações, embora os animais que receberam a telaem ponte tiveram aderências mais firmes e intensas à parede abdominal. CONCLUSÕES: As duas técnicas utilizadas para correção da hérnia incisional em coelhos não mostraram diferenças significantes quanto a força de ruptura, análise histológica e morfométrica. O número de complicações foi semelhante, porém a aderência de órgãos da cavidade abdominal à área de cicatriz foi muito mais intensa no grupo em que a tela foi colocadaem ponte .pt
dc.description.abstractPURPOSE: To compare two different incisional hernia repair techniques (repair with a polypropylene mesh reinforcement on the peritonium-aponeurosis versus polypropylene mesh sutured to the borders of the hernial ring as a bridge) in rabbits. METHODS: Incisional hernia was experimentally developed through a 4-cm median incision in 60 rabbits. After 30 days, half of the animals were operated for primary wall closure and placement of a polypropylene mesh reinforcement, while the other half had a polypropylene mesh sutured to the borders of the hernial ring as a bridge. Clinical development, scar breaking strength, as well as gross, microscopic and morphometric parameters were evaluated in all animals 30, 60, and 90 days after repair. RESULTS: No significant differences in breaking strength or histological parameters were observed between groups at any time point studied. No statistical difference regarding complications was detected, although denser and firmer adhesions to the abdominal wall were seen after the mesh was placed as abridge . CONCLUSIONS: No significant differences between the incisional hernia repair techniques assessed were observed regarding breaking strength, and histological and morphometric parameters. The number of complications was similar in both study groups. However, adhesion of abdominal cavity organs to the scar area was much denser after the placement of a mesh to bridge the defect.en
dc.description.affiliationUNESP Botucatu Medical School Department of Surgery and Orthopedics
dc.description.affiliationUNESP Botucatu Medical School Department of Internal Medicine
dc.description.affiliationUnespUNESP Botucatu Medical School Department of Surgery and Orthopedics
dc.description.affiliationUnespUNESP Botucatu Medical School Department of Internal Medicine
dc.format.extent423-427
dc.identifierhttp://dx.doi.org/10.1590/S0102-86502010000500007
dc.identifier.citationActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 25, n. 5, p. 423-427, 2010.
dc.identifier.doi10.1590/S0102-86502010000500007
dc.identifier.fileS0102-86502010000500007.pdf
dc.identifier.issn0102-8650
dc.identifier.lattes5518720125698768
dc.identifier.lattes3191894452135777
dc.identifier.lattes3769255547738283
dc.identifier.scieloS0102-86502010000500007
dc.identifier.urihttp://hdl.handle.net/11449/11524
dc.identifier.wosWOS:000282219500007
dc.language.isoeng
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.relation.ispartofActa Cirúrgica Brasileira
dc.relation.ispartofjcr0.933
dc.relation.ispartofsjr0,395
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectHérnia Ventralpt
dc.subjectPolipropilenospt
dc.subjectTelas Cirúrgicaspt
dc.subjectCoelhospt
dc.subjectHernia, Ventralen
dc.subjectPolypropylenesen
dc.subjectSurgical Meshen
dc.subjectRabbitsen
dc.titleComparative study between two techniques of incisional hernia repair with polypropylene mesh in rabbitsen
dc.title.alternativeEstudo comparativo entre duas técnicas de tratamento da hérnia incisional em coelhos utilizando a tela de polipropilenopt
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes5518720125698768[2]
unesp.author.lattes3769255547738283
unesp.author.lattes3191894452135777[3]
unesp.author.orcid0000-0002-0390-1061[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentCirurgia e Ortopedia - FMBpt
unesp.departmentClínica Médica - FMBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0102-86502010000500007.pdf
Tamanho:
158.36 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: