Logotipo do repositório
 

Publicação:
Peel bond strength of resilient liner modified by the addition of antimicrobial agents to denture base acrylic resin

dc.contributor.authorAlcantara, Cristiane S.
dc.contributor.authorde Macedo, Allana F. C.
dc.contributor.authorGurgel, Bruno C. V.
dc.contributor.authorJorge, Janaina Habib [UNESP]
dc.contributor.authorNeppelenbroek, Karin H.
dc.contributor.authorUrban, Vanessa M.
dc.contributor.institutionCtr Super Studies Maceio CESMAC
dc.contributor.institutionUniversidade Federal do Rio Grande do Norte (UFRN)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual de Ponta Grossa (UEPG)
dc.date.accessioned2014-05-20T13:46:27Z
dc.date.available2014-05-20T13:46:27Z
dc.date.issued2012-11-01
dc.description.abstractIn order to prolong the clinical longevity of resilient denture relining materials and reduce plaque accumulation, incorporation of antimicrobial agents into these materials has been proposed. However, this addition may affect their properties. Objective: This study evaluated the effect of the addition of antimicrobial agents into one soft liner (Soft Confort, Dencril) on its peel bond strength to one denture base (QC 20, Dentsply). Material and Methods: Acrylic specimens (n=9) were made (75x10x3 mm) and stored in distilled water at 37 degrees C for 48 h. The drug powder concentrations (nystatin 500,000U - G2; nystatin 1,000,000U - G3; miconazole 125 mg - G4; miconazole 250 mg - G5; ketoconazole 100 mg - G6; ketoconazole 200 mg - G7; chlorhexidine diacetate 5% - G8; and 10% chlorhexidine diacetate - G9) were blended with the soft liner powder before the addition of the soft liner liquid. A group (G1) without any drug incorporation was used as control. Specimens (n=9) (75x10x6 mm) were plasticized according to the manufacturers' instructions and stored in distilled water at 37 degrees C for 24 h. Relined specimens were then submitted to a 180-degree peel test at a crosshead speed of 10 mm/min. Data (MPa) were analyzed by analysis of variance (alpha=0.05) and the failure modes were visually classified. Results: No significant difference was found among experimental groups (p=0.148). Cohesive failure located within the resilient material was predominantly observed in all tested groups. Conclusions: Peel bond strength between the denture base and the modified soft liner was not affected by the addition of antimicrobial agents.en
dc.description.affiliationCtr Super Studies Maceio CESMAC, Fac Hlth & Life Sci, Maceio, AL, Brazil
dc.description.affiliationFed Univ Rio Grande Norte UFRN, Dept Dent, Natal, RN, Brazil
dc.description.affiliationUniv Estadual Paulista UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil
dc.description.affiliationUniv São Paulo, Bauru Sch Dent, Bauru, SP, Brazil
dc.description.affiliationPonta Grossa State Univ UEPG, Dept Dent, Ponta Grossa, PR, Brazil
dc.description.affiliationUnespUniv Estadual Paulista UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil
dc.format.extent607-612
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572012000600004
dc.identifier.citationJournal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 20, n. 6, p. 607-612, 2012.
dc.identifier.fileS1678-77572012000600004.pdf
dc.identifier.issn1678-7757
dc.identifier.scieloS1678-77572012000600004
dc.identifier.urihttp://hdl.handle.net/11449/16442
dc.identifier.wosWOS:000313707300004
dc.language.isoeng
dc.publisherUniversidade de São Paulo (USP), Faculdade de Odontologia de Bauru
dc.relation.ispartofJournal of Applied Oral Science
dc.relation.ispartofjcr1.709
dc.relation.ispartofsjr0,645
dc.rights.accessRightsAcesso abertopt
dc.sourceWeb of Science
dc.subjectAntifungal agentsen
dc.subjectTensile strengthen
dc.subjectStomatitisen
dc.subjectDenture basesen
dc.titlePeel bond strength of resilient liner modified by the addition of antimicrobial agents to denture base acrylic resinen
dc.typeArtigopt
dcterms.licensehttp://www.scielo.br/revistas/jaos/paboutj.htm
dcterms.rightsHolderUniv São Paulo Fac Odontologia Bauru
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.orcid0000-0001-7086-2667[5]
unesp.author.orcid0000-0002-9135-3455[4]
unesp.author.orcid0000-0003-3320-8783[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1678-77572012000600004.pdf
Tamanho:
233.3 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: