Publicação: Effect of thermal cycling on denture base and autopolymerizing reline resins
dc.contributor.author | Silva, Cíntia de Souza [UNESP] | |
dc.contributor.author | Machado, Ana Lucia [UNESP] | |
dc.contributor.author | Chaves, Carolina de Andrade Lima [UNESP] | |
dc.contributor.author | Pavarina, Ana Claudia [UNESP] | |
dc.contributor.author | Vergani, Carlos Eduardo [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:29:06Z | |
dc.date.available | 2014-05-27T11:29:06Z | |
dc.date.issued | 2013-05-01 | |
dc.description.abstract | Objective: This study evaluated the fracture toughness (FT) of denture base and autopolymerizing reline resins, with and without thermocycling (T). Material and Methods: Specimens of each material (denture base acrylic resin - Lucitone 550 - L; autopolymerizing reline resins - Ufi Gel Hard-UH, Tokuyama Rebase II-TR, New Truliner-NT and Kooliner-K), were produced, notched and divided into two groups (n = 10): CG (control group of autopolymerizing reline resins and L): FT tests were performed after polymerization; TG (thermocycled group): FT tests were performed after T (5°C and 55°C for 5,000 cycles). Results: Results (MPa.m1/2) were analyzed by two-way ANOVA and Tukey's test (p=0.05). L exhibited the highest FT mean values in both groups (CG - 2.33; TG -2.17). For the CG groups, NT showed the highest FT (1.64) among the autopolymerizing reline resins, and K the lowest (1.04). After T, when the autopolymerizing reline resins were compared, a statistically significant difference in FT was found only between the NT (1.46) and TR (1.00). Conclusions: Thermocycling increased the FT of K and did not influence the FT of L, UH, TR and NT. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics School of Dentistry Araraquara UNESP - Univ. Estadual Paulista, Araraquara, SP | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics School of Dentistry Araraquara UNESP - Univ. Estadual Paulista, Araraquara, SP | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.format.extent | 219-224 | |
dc.identifier | http://www.scielo.br/scielo.php?pid=S1678-77572013000300219&script=sci_arttext | |
dc.identifier.citation | Journal of Applied Oral Science, v. 21, n. 3, p. 219-224, 2013. | |
dc.identifier.file | 2-s2.0-84880067841.pdf | |
dc.identifier.issn | 1678-7757 | |
dc.identifier.issn | 1678-7765 | |
dc.identifier.lattes | 8000248781842587 | |
dc.identifier.lattes | 8867670539105403 | |
dc.identifier.lattes | 3003130522427820 | |
dc.identifier.orcid | 0000-0002-7375-4714 | |
dc.identifier.scielo | S1678-77572013000300219 | |
dc.identifier.scopus | 2-s2.0-84880067841 | |
dc.identifier.uri | http://hdl.handle.net/11449/75334 | |
dc.identifier.wos | WOS:000324571100003 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Applied Oral Science | |
dc.relation.ispartofjcr | 1.709 | |
dc.relation.ispartofsjr | 0,645 | |
dc.rights.accessRights | Acesso aberto | pt |
dc.source | Scopus | |
dc.subject | Acrylic resins | |
dc.subject | Denture bases | |
dc.subject | Thermic treatment | |
dc.title | Effect of thermal cycling on denture base and autopolymerizing reline resins | en |
dc.type | Artigo | pt |
dcterms.license | http://www.scielo.br/revistas/jaos/paboutj.htm | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isDepartmentOfPublication.latestForDiscovery | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.author.lattes | 8000248781842587[2] | |
unesp.author.lattes | 8867670539105403[4] | |
unesp.author.lattes | 3003130522427820[5] | |
unesp.author.orcid | 0000-0002-7375-4714[5] | |
unesp.author.orcid | 0000-0002-9231-1994[4] | |
unesp.author.orcid | 0000-0002-2718-428X[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-84880067841.pdf
- Tamanho:
- 1.68 MB
- Formato:
- Adobe Portable Document Format