Logo do repositório
 

Insertion torque and pull-out strength of orthodontic mini-implants comparing manual and motor insertion methods

dc.contributor.authorAssunção, Viviane A.
dc.contributor.authorLunardi, Nadia
dc.contributor.authorBoeck, Eloisa M.
dc.contributor.authorGeraldo-Vaz, Luis [UNESP]
dc.contributor.authorBoeck-Neto, Rodolfo J.
dc.contributor.authorLuvizuto, Eloa R. [UNESP]
dc.contributor.institutionCentro Universitário de Araraquara (UNIARA)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-10-21T13:10:47Z
dc.date.available2015-10-21T13:10:47Z
dc.date.issued2015-05-01
dc.description.affiliationDepartment of Orthodontics School of Dentistry Araraquara University Center (UNIARA) Araraquara São Paulo, Brazil
dc.description.affiliationDepartment of Surgery School of Dentistry Araraquara University Center (UNIARA) Araraquara São Paulo, Brazil
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics School of Dentistry São Paulo State University (UNESP) Araraquara São Paulo, Brazil
dc.description.affiliationUnespDepartment of Surgery and Integrated Clinic UNESP–Univ Estadual Paulista Araçatuba Dental School São Paulo, Brazil
dc.format.extent993-996
dc.identifierhttp://ovidsp.tx.ovid.com/sp-3.17.0a/ovidweb.cgi?QS2=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
dc.identifier.citationJournal Of Craniofacial Surgery. Philadelphia: Lippincott Williams &wilkins, v. 26, n. 3, p. 993-996, 2015.
dc.identifier.doi10.1097/SCS.0000000000001582
dc.identifier.issn1049-2275
dc.identifier.urihttp://hdl.handle.net/11449/128540
dc.identifier.wosWOS:000355236700151
dc.language.isoeng
dc.publisherLippincott Williams &wilkins
dc.relation.ispartofJournal Of Craniofacial Surgery
dc.relation.ispartofjcr0.772
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleInsertion torque and pull-out strength of orthodontic mini-implants comparing manual and motor insertion methodsen
dc.typeArtigopt
dcterms.rightsHolderLippincott Williams &wilkins
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentCirurgia e Clínica Integrada - FOApt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos