Photoelastic analysis to compare implant-retained and conventional obturator dentures
dc.contributor.author | Goiato, Marcelo Coelho [UNESP] | |
dc.contributor.author | Ribeiro, Paula do Prado [UNESP] | |
dc.contributor.author | Pellizzer, Eduardo Piza [UNESP] | |
dc.contributor.author | Pesqueira, Aldieris Alves [UNESP] | |
dc.contributor.author | Haddad, Marcela Filie [UNESP] | |
dc.contributor.author | Santos, Daniela Micheline dos [UNESP] | |
dc.contributor.author | Moreno, Amalia [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2013-09-30T18:30:25Z | |
dc.date.accessioned | 2014-05-20T13:43:55Z | |
dc.date.available | 2013-09-30T18:30:25Z | |
dc.date.available | 2014-05-20T13:43:55Z | |
dc.date.issued | 2012-06-01 | |
dc.description.abstract | The use of photoelastic analysis contributes to the rehabilitation of patients with oral-sinus-nasal sequelae, which in turn affect important functions such as chewing, swallowing, and speech. The prosthetic rehabilitation with implant-retained dentures is a suitable treatment option. The purpose of this study was to verify, by using a photoelastic analysis, the stress distribution in implant-retained palatal obturator dentures (relined or not) associated with different attachment systems (O-ring, bar-clip, and bar-clip associated with distally placed O-rings). Two photoelastic models were obtained from an experimental maxillary cast presenting an oral-nasal communication. One model had two 13-mm length implants placed on the left region. A total of eight colorless maxillary obturators were fabricated and subsequently four of them were relined with soft silicone soft, and three had attachment systems associated. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a 100-N load was applied at 10 mm/s. The results showed that the denture relining influenced the distribution and amount of stress on the models. The O-ring group displayed the lowest stress levels, followed by bar-clip system associated with distally placed O-rings and bar-clip groups. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.6.061203] | en |
dc.description.affiliation | Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.format.extent | 4 | |
dc.identifier | http://dx.doi.org/10.1117/1.JBO.17.6.061203 | |
dc.identifier.citation | Journal of Biomedical Optics. Bellingham: Spie-soc Photo-optical Instrumentation Engineers, v. 17, n. 6, p. 4, 2012. | |
dc.identifier.doi | 10.1117/1.JBO.17.6.061203 | |
dc.identifier.file | WOS000305582500010.pdf | |
dc.identifier.issn | 1083-3668 | |
dc.identifier.lattes | 9719883814872582 | |
dc.identifier.lattes | 5581364193525500 | |
dc.identifier.orcid | 0000-0002-3800-3050 | |
dc.identifier.uri | http://hdl.handle.net/11449/15361 | |
dc.identifier.wos | WOS:000305582500010 | |
dc.language.iso | eng | |
dc.publisher | Spie-soc Photo-optical Instrumentation Engineers | |
dc.relation.ispartof | Journal of Biomedical Optics | |
dc.relation.ispartofjcr | 2.367 | |
dc.relation.ispartofsjr | 0,918 | |
dc.rights.accessRights | Acesso aberto | pt |
dc.source | Web of Science | |
dc.subject | dental implant | en |
dc.subject | maxillectomy | en |
dc.subject | photoelastic | en |
dc.subject | denture liners | en |
dc.title | Photoelastic analysis to compare implant-retained and conventional obturator dentures | en |
dc.type | Artigo | pt |
dcterms.license | http://spie.org/x1125.xml | |
dcterms.rightsHolder | Spie-soc Photo-optical Instrumentation Engineers | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 9719883814872582 | |
unesp.author.lattes | 5581364193525500 | |
unesp.author.lattes | 2336450644149867[4] | |
unesp.author.orcid | 0000-0002-3800-3050[1] | |
unesp.author.orcid | 0000-0003-3020-5253[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |
Arquivos
Pacote original
1 - 1 de 1
Carregando...
- Nome:
- WOS000305582500010.pdf
- Tamanho:
- 1.19 MB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: