Logo do repositório
 

Photoelastic analysis to compare implant-retained and conventional obturator dentures

dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorRibeiro, Paula do Prado [UNESP]
dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.authorPesqueira, Aldieris Alves [UNESP]
dc.contributor.authorHaddad, Marcela Filie [UNESP]
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.authorMoreno, Amalia [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:25Z
dc.date.accessioned2014-05-20T13:43:55Z
dc.date.available2013-09-30T18:30:25Z
dc.date.available2014-05-20T13:43:55Z
dc.date.issued2012-06-01
dc.description.abstractThe use of photoelastic analysis contributes to the rehabilitation of patients with oral-sinus-nasal sequelae, which in turn affect important functions such as chewing, swallowing, and speech. The prosthetic rehabilitation with implant-retained dentures is a suitable treatment option. The purpose of this study was to verify, by using a photoelastic analysis, the stress distribution in implant-retained palatal obturator dentures (relined or not) associated with different attachment systems (O-ring, bar-clip, and bar-clip associated with distally placed O-rings). Two photoelastic models were obtained from an experimental maxillary cast presenting an oral-nasal communication. One model had two 13-mm length implants placed on the left region. A total of eight colorless maxillary obturators were fabricated and subsequently four of them were relined with soft silicone soft, and three had attachment systems associated. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a 100-N load was applied at 10 mm/s. The results showed that the denture relining influenced the distribution and amount of stress on the models. The O-ring group displayed the lowest stress levels, followed by bar-clip system associated with distally placed O-rings and bar-clip groups. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.6.061203]en
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.format.extent4
dc.identifierhttp://dx.doi.org/10.1117/1.JBO.17.6.061203
dc.identifier.citationJournal of Biomedical Optics. Bellingham: Spie-soc Photo-optical Instrumentation Engineers, v. 17, n. 6, p. 4, 2012.
dc.identifier.doi10.1117/1.JBO.17.6.061203
dc.identifier.fileWOS000305582500010.pdf
dc.identifier.issn1083-3668
dc.identifier.lattes9719883814872582
dc.identifier.lattes5581364193525500
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.urihttp://hdl.handle.net/11449/15361
dc.identifier.wosWOS:000305582500010
dc.language.isoeng
dc.publisherSpie-soc Photo-optical Instrumentation Engineers
dc.relation.ispartofJournal of Biomedical Optics
dc.relation.ispartofjcr2.367
dc.relation.ispartofsjr0,918
dc.rights.accessRightsAcesso abertopt
dc.sourceWeb of Science
dc.subjectdental implanten
dc.subjectmaxillectomyen
dc.subjectphotoelasticen
dc.subjectdenture linersen
dc.titlePhotoelastic analysis to compare implant-retained and conventional obturator denturesen
dc.typeArtigopt
dcterms.licensehttp://spie.org/x1125.xml
dcterms.rightsHolderSpie-soc Photo-optical Instrumentation Engineers
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes9719883814872582
unesp.author.lattes5581364193525500
unesp.author.lattes2336450644149867[4]
unesp.author.orcid0000-0002-3800-3050[1]
unesp.author.orcid0000-0003-3020-5253[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
WOS000305582500010.pdf
Tamanho:
1.19 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: