Logotipo do repositório
 

Publicação:
Myocardial protection by continuous, blood, antegrade-retrograde cardioplegia in rabbits

dc.contributor.authorMartins, Antonio Sérgio [UNESP]
dc.contributor.authorSilva, Marcos Augusto de Moraes [UNESP]
dc.contributor.authorPadovani, Carlos Roberto [UNESP]
dc.contributor.authorMatsubara, Beatriz Bojikian [UNESP]
dc.contributor.authorBraile, Domingo Marcolino
dc.contributor.authorCataneo, Antonio José Maria [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionFaculty of Medicine Surgery Department
dc.date.accessioned2014-05-20T15:13:57Z
dc.date.available2014-05-20T15:13:57Z
dc.date.issued2007-02-01
dc.description.abstractOBJETIVO: Estudar a eficácia e a segurança da cardioplegia sanguínea, aterógrada-retrógrada contínua, por meio da avaliação da função ventricular. MÉTODOS: Os coelhos foram divididos em quatro grupos: Controle-C(n=10); isquêmico e cardioplegia cristaloide-IC(n=10; isquêmico e cardioplegia sanguínea-IB(n=10; isquêmico sem cardioplegia-INC(n=10. Após o período isquêmico do protocolo a função ventricular foi analisada pela técnica do balão intra-ventricular. RESULTADOS: a pressão desenvolvida intra-ventricular (IVDP) foi: C(92,90&plusmn; 6,86mmHg); IC(77,78&plusmn; 6,15mmHg); IB(93,64 &plusmn;5,09mmHg); INC(39,46 &plusmn;8,91mmHg) p<0,005. a primeira derivada temporal da pressão ventricular na sua deflexão positiva: C(1137,50&plusmn; 92,23mmHg/sec); IC(1130,62 &plusmn;43,78mmHg/sec); IB(1187,58&plusmn; 88,38mmHg/sec); INC(620,02&plusmn; 43,80mmHg/se) p<0,005. A primeira derivada da pressão ventricular na sua deflexão negativa: C(770,00&plusmn; 73,41mmHg/sec); IC(610,03 &plusmn;47,43mmg/sec); IB(762,53 &plusmn;46,02mmHg/sec); INC(412,35 &plusmn;84,36mmHg/sec) p<0,005. A relação do coeficiente angular logarítmico foi: C(0,108&plusmn; 0,02); IC(0,159&plusmn; 0,038); IB(0,114 &plusmn;0,016); INC(0,175&plusmn; 0,038) p<0,05. CONCLUSÃO: No modelo experimental estudado o grupo isquêmico protegido pela cardioplegia sanguínea apresentou melhor função ventricular que os grupos protegidos por cardioplegia cristalóide e não protegido.pt
dc.description.abstractPURPOSE: To study the effectiveness of the continuous, blood, antegrade-retrograde cardioplegia in an experimental model of isolated heart, evaluating ventricular function. METHODS: Rabbits were divided into four groups: Control-C(n=10); ischemic crystalloid cardioplegia-IC(n=10); ischemic blood cardioplegia-IB(n=10); ischemic non cardioplegia-INC(n=10). After the ischemic protocol period the ventricular function was analyzed by the intra-ventricular balloon technique. RESULTS: the intra-ventricular developed pressure (IVDP) was: C(92.90&plusmn;6.86mmHg); IC(77.78&plusmn;6.15mmHg); IB(93.64&plusmn;5.09mmHg); INC(39.46 &plusmn;8.91mmHg) p<0.005. The first derivative of intra-ventricular pressure in its positive deflection was: C(1137.50&plusmn; 92.23mmHg/sec); IC(1130.62 &plusmn;43.78mmHg/sec); IB(1187.58&plusmn; 88.38mmHg/sec); INC(620.02&plusmn; 43.80mmHg/se) p<0.005. The first derivate pressure in its negative deflection was: C(770.00&plusmn; 73.41mmHg/sec); IC(610.03 &plusmn;47.43mmg/sec); IB(762.53 &plusmn;46.02mmHg/sec); INC(412.35 &plusmn;84.36mmHg/sec) p<0,005. The stress-strain angular logarithmic coefficient was: C(0.108&plusmn; 0.02); IC(0.159&plusmn; 0.038); IB(0.114 &plusmn;0.016); INC(0.175&plusmn; 0.038) p<0.05. CONCLUSION: The ischemic group protected by blood cardioplegia showed better ventricular function than ischemic group protected by crystalloid cardioplegia and the non protected group.en
dc.description.affiliationUNESP Surgery Department
dc.description.affiliationUNESP Mathematics and Statistical Department
dc.description.affiliationUNESP Cardiology Department
dc.description.affiliationFaculty of Medicine Surgery Department
dc.description.affiliationUnespUNESP Surgery Department
dc.description.affiliationUnespUNESP Mathematics and Statistical Department
dc.description.affiliationUnespUNESP Cardiology Department
dc.format.extent43-46
dc.identifierhttp://dx.doi.org/10.1590/S0102-86502007000100008
dc.identifier.citationActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 22, n. 1, p. 43-46, 2007.
dc.identifier.doi10.1590/S0102-86502007000100008
dc.identifier.fileS0102-86502007000100008.pdf
dc.identifier.issn0102-8650
dc.identifier.lattes6990977122340795
dc.identifier.lattes8727897080522289
dc.identifier.lattes9919910234219937
dc.identifier.scieloS0102-86502007000100008
dc.identifier.urihttp://hdl.handle.net/11449/28998
dc.language.isoeng
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.relation.ispartofActa Cirúrgica Brasileira
dc.relation.ispartofjcr0.933
dc.relation.ispartofsjr0,395
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectFunção Ventricularpt
dc.subjectIsquemiapt
dc.subjectMiocárdiopt
dc.subjectModelos Animaispt
dc.subjectParada Cardíaca Induzidapt
dc.subjectCoelhospt
dc.subjectVentricular Functionen
dc.subjectIschemiaen
dc.subjectMyocardiumen
dc.subjectAnimal, Modelsen
dc.subjectHeart Arrest, Induceden
dc.subjectRabbitsen
dc.titleMyocardial protection by continuous, blood, antegrade-retrograde cardioplegia in rabbitsen
dc.title.alternativeProteção miocárdica da cardioplegia sanguínea contínua, anterógrada e retrógrada em coelhospt
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6990977122340795
unesp.author.lattes8727897080522289[3]
unesp.author.lattes9919910234219937
unesp.author.lattes1919165905574226[6]
unesp.author.orcid0000-0003-2330-9337[6]
unesp.author.orcid0000-0002-7719-9682[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatupt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentCirurgia e Ortopedia - FMBpt
unesp.departmentClínica Médica - FMBpt
unesp.departmentBioestatística - IBBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0102-86502007000100008.pdf
Tamanho:
399.18 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: