Logotipo do repositório
 

Publicação:
Analysis of cardiovascular system responses to forced vital capacity in COPD

dc.contributor.authorMendes, Felipe A. R.
dc.contributor.authorMoreno, Isadora L. [UNESP]
dc.contributor.authorDurand, Marina T.
dc.contributor.authorPastre, Carlos M. [UNESP]
dc.contributor.authorRamos, Ercy M. C. [UNESP]
dc.contributor.authorVanderlei, Luiz C. M. [UNESP]
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:23:15Z
dc.date.available2014-05-20T13:23:15Z
dc.date.issued2011-04-01
dc.description.abstractCONTEXTUALIZAÇÃO: O teste de capacidade vital forçada (CVF) é rotineiramente realizado na avaliação da função pulmonar de pacientes com doença pulmonar obstrutiva crônica (DPOC). Entretanto, permanece pouco compreendida a influência do teste de CVF sobre o sistema cardiovascular de pacientes com DPOC. OBJETIVOS: Analisar o comportamento da frequência cardíaca (FC), pressão arterial (PA) e variabilidade da frequência cardíaca (VFC) no teste de CVF na DPOC. MÉTODOS: Dezenove homens com DPOC (72 ± 7 anos, no estágio de gravidade GOLD I=3, II=5, III=7 e IV=4 pacientes) realizaram a manobra de CVF e tiveram sua FC monitorada durante todo o exame, e a VFC analisada nos domínios do tempo (rMSSD) e da frequência (BF, AF e BF/AF) durante o repouso, antes e após a melhor manobra de CVF. A PA foi analisada no repouso, imediatamente ao final da manobra de CVF e 10 minutos após o término de todos os testes. RESULTADOS: Ao início da manobra de CVF, a FC reduziu (p<0,001) e, em seguida, aumentou progressivamente até o final do teste (p<0,001). Após término da manobra, a FC continuou a aumentar até atingir um pico (p<0,001) e depois caiu rapidamente a valores inferiores aos de repouso (p<0,001) e retornou ao seu valor basal. A PA e os índices da VFC não sofreram alterações nos períodos analisados. CONCLUSÃO: O teste de CVF influencia o comportamento da FC, sem alterar o seu controle autonômico, bem como a PA em pacientes com DPOC nos períodos analisados.pt
dc.description.abstractBACKGROUND: The forced vital capacity (FVC) test is routinely performed to evaluate pulmonary function in patients with chronic obstructive pulmonary disease (COPD). However, the influence of the FVC maneuver on the cardiovascular system of patients with COPD is poorly understood. OBJECTIVES: To analyze the behavior of heart rate (HR), blood pressure (BP) and heart rate variability (HRV) during the FVC test in COPD patients. METHODS: Nineteen men with COPD (72±7 years, GOLD stage I=3, II=5, III=7 and IV=4 patients) performed the FVC test while having their HR monitored. HRV was assessed in time (rMSSD) and frequency domains (LF, HF and LF/HF) at rest, before and after the best FVC maneuver. BP was measured at rest, immediately before and at the end of the test, as well as 10 minutes after the end of the test. RESULTS: At the beginning of the FVC maneuver, HR decreased (p<0.001) and then increased gradually until the end of the test (p<0.001). After the end of maneuver, HR continued to increase until it reached a peak (p<0.001), and then it fell quickly to below at-rest values (p<0.001) prior to returning to baseline. The BP and HRV indices did not change during the assessment. CONCLUSION: The FVC test influences the behavior of COPD patient HR without changing autonomic control or BP.en
dc.description.affiliationUniversidade de São Paulo School of Medicine Physical Therapy Department, Speech Therapy and Occupational Therapy
dc.description.affiliationUniversidade Estadual Paulista Faculty of Science and Technology Physical Therapy Department
dc.description.affiliationUSP Department of Physiology
dc.description.affiliationUnespUniversidade Estadual Paulista Faculty of Science and Technology Physical Therapy Department
dc.description.sponsorshipFundação para o Desenvolvimento da UNESP (FUNDUNESP)
dc.format.extent102-108
dc.identifierhttp://dx.doi.org/10.1590/S1413-35552011000200004
dc.identifier.citationBrazilian Journal of Physical Therapy. Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia , v. 15, n. 2, p. 102-108, 2011.
dc.identifier.doi10.1590/S1413-35552011000200004
dc.identifier.fileS1413-35552011000200004.pdf
dc.identifier.issn1413-3555
dc.identifier.scieloS1413-35552011000200004
dc.identifier.urihttp://hdl.handle.net/11449/6985
dc.identifier.wosWOS:000292278100004
dc.language.isoeng
dc.publisherAssociação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
dc.relation.ispartofBrazilian Journal of Physical Therapy
dc.relation.ispartofjcr1.699
dc.relation.ispartofsjr0,802
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectdoença pulmonar obstrutiva crônicapt
dc.subjectespirometriapt
dc.subjectcapacidade vitalpt
dc.subjectfrequência cardíacapt
dc.subjectsistema nervoso autônomopt
dc.subjectchronic obstructive pulmonary diseaseen
dc.subjectspirometryen
dc.subjectvital capacityen
dc.subjectheart rateen
dc.subjectautonomic nervous systemen
dc.titleAnalysis of cardiovascular system responses to forced vital capacity in COPDen
dc.title.alternativeAnálise das respostas do sistema cardiovascular ao teste de capacidade vital forçada na DPOCpt
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/rbfis/paboutj.htm
dspace.entity.typePublication
unesp.author.lattes2761396544058606[4]
unesp.author.orcid0000-0002-1891-3153[6]
unesp.author.orcid0000-0002-3310-7336[5]
unesp.author.orcid0000-0002-0213-6679[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências e Tecnologia, Presidente Prudentept
unesp.departmentFisioterapia - FCTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1413-35552011000200004.pdf
Tamanho:
198.61 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: