Comparison of compressive strength between three different plates for mandibular angle fractures fixation

dc.contributor.authorNegreiros Lyrio, Mariana C. [UNESP]
dc.contributor.authorMonnazzi, Marcelo Silva [UNESP]
dc.contributor.authorMoraes, Marcio de [UNESP]
dc.contributor.authorVieira, Eduardo Hochuli [UNESP]
dc.contributor.authorReis, José Mauricio Nunes [UNESP]
dc.contributor.authorPereira-Filho, Valfrido Antonio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-08-06T16:12:44Z
dc.date.available2015-08-06T16:12:44Z
dc.date.issued2013
dc.description.abstractThe present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Diagnóstico e Cirurgia, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801-903, SP, Brasil
dc.description.affiliationUnespDental School of Araraquara, Department of Diagnosis and Oral and Maxillofacial Surgery, Universidade Estadual Paulista, Unesp, Rua Humaita, 1680, 2° andar, Araraquara, São Paulo Cep 14801-903, Brazil
dc.description.affiliationUnespDental School of Araraquara, Department of Diagnosis and Oral and Maxillofacial Surgery, Universidade Estadual Paulista, Unesp, Rua Humaita, 1680, 2° andar, Araraquara, São Paulo Cep 14801-903, Brazil. Electronic address: monnazzi@ig.com.br.
dc.format.extent277-280
dc.identifier.citationJournal of Cranio-Maxillo-Facial Surgery, v. 42, n. 5, p. 277-280, 2013.
dc.identifier.doi10.1016/j.jcms.2013.10.005
dc.identifier.issn1010-5182
dc.identifier.lattes6853485483683678
dc.identifier.lattes7102492567043518
dc.identifier.lattes3933940257808182
dc.identifier.urihttp://hdl.handle.net/11449/125658
dc.language.isoeng
dc.relation.ispartofJournal of Cranio-Maxillo-Facial Surgery
dc.relation.ispartofjcr1.960
dc.relation.ispartofsjr1,033
dc.rights.accessRightsAcesso restrito
dc.sourceCurrículo Lattes
dc.subjectBite forceen
dc.subjectBone plateen
dc.subjectCompressive strengthen
dc.subjectMandibular fractureen
dc.titleComparison of compressive strength between three different plates for mandibular angle fractures fixationen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6853485483683678[4]
unesp.author.lattes7102492567043518
unesp.author.lattes3933940257808182
unesp.author.orcid0000-0003-4040-9313[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos