In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants
dc.contributor.author | Barros, Luiz-Antônio-Borelli [UNESP] | |
dc.contributor.author | da Silva, Caio-Fossalussa | |
dc.contributor.author | Camargos, Germana-de Villa | |
dc.contributor.author | Jr, Elcio Marcantonio [UNESP] | |
dc.contributor.author | de Oliveira, Guilherme-José-Pimentel-Lopes | |
dc.contributor.author | Barros-Filho, Luiz-Antonio-Borelli | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | Universidade Federal de Uberlândia (UFU) | |
dc.contributor.institution | UNIARA | |
dc.date.accessioned | 2022-04-28T19:50:57Z | |
dc.date.available | 2022-04-28T19:50:57Z | |
dc.date.issued | 2022-01-01 | |
dc.description.abstract | Background: The aim of this in vitro study was to evaluate the influence of the cortical thickness on the primary stability of short and conventional-sized implants with two types of prosthetic connection. Material and Methods: Seventy-two implants were used. These implants were placed in polyurethane blocks that simulated low-density bone tissue (type IV bone), with two bone cortical heights (type I bone): 1mm and 3mm. The implants were divided into 6 groups with 12 implants each according to the type of prosthetic connections (external-hexagon -EH and morse taper- MT) and implant sizes (conventional- 4x10mm and short 5x5mm; 5.5x5mm; 5x6mm; 5.5x6mm). Insertion torque (IT) and resonance frequency analyzes (RFA) were performed to evaluate the primary stability of the implants. Results: All implants installed in blocks with 3mm of cortical thickness showed greater IT than those installed in 1mm. The short-sized MT implants had a higher IT than conventional implants of the same connection. Short-sized EH implants showed less IT than short-sized MT implants in blocks with 3mm of cortical. In blocks with 1mm of cortical, conventional EH implants had a higher IT compared to short-sized EH implants. The conventional sized implants presented higher RFA values despite the thickness of the cortical in the blocks. Conclusions: The greater bone cortical thickness and implants size provides greater primary stability of the implants regardless the prosthetic connection. | en |
dc.description.affiliation | DDS Phd. Department of Diagnosis and Surgery Univ. Est. Paul. - UNESP | |
dc.description.affiliation | MS. Department of Periodontology/Implantology Dental School Federal University of Uberlândia - UFU | |
dc.description.affiliation | DDS. Department of Periodontology/Implantology Dental School Federal University of Uberlândia - UFU | |
dc.description.affiliation | DDS. Department of Diagnosis and Surgery Univ. Est. Paul. - UNESP | |
dc.description.affiliation | DDS. Department of Oral Surgery Dental School Universidade de Araraquara UNIARA | |
dc.description.affiliationUnesp | DDS Phd. Department of Diagnosis and Surgery Univ. Est. Paul. - UNESP | |
dc.description.affiliationUnesp | DDS. Department of Diagnosis and Surgery Univ. Est. Paul. - UNESP | |
dc.format.extent | 138-143 | |
dc.identifier | http://dx.doi.org/10.4317/JCED.58886 | |
dc.identifier.citation | Journal of Clinical and Experimental Dentistry, v. 14, n. 2, p. 138-143, 2022. | |
dc.identifier.doi | 10.4317/JCED.58886 | |
dc.identifier.issn | 1989-5488 | |
dc.identifier.scopus | 2-s2.0-85124980361 | |
dc.identifier.uri | http://hdl.handle.net/11449/223495 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Clinical and Experimental Dentistry | |
dc.source | Scopus | |
dc.subject | Implants connection | |
dc.subject | implants macrostructure | |
dc.subject | primary stability | |
dc.title | In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants | en |
dc.type | Artigo | |
dspace.entity.type | Publication |